background image

Huawei FusionServer Pro 2488 V5 Server

V100R005

Technical White Paper

Issue

11

Date

2020-09-03

HUAWEI TECHNOLOGIES CO., LTD.

Summary of Contents for FusionServer Pro 2488 V5

Page 1: ...Huawei FusionServer Pro 2488 V5 Server V100R005 Technical White Paper Issue 11 Date 2020 09 03 HUAWEI TECHNOLOGIES CO LTD ...

Page 2: ...cribed in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject to change without notice Every effort has been made in the prep...

Page 3: ...k which if not avoided will result in death or serious injury Indicates a hazard with a medium level of risk which if not avoided could result in death or serious injury Indicates a hazard with a low level of risk which if not avoided could result in minor or moderate injury Indicates a potentially hazardous situation which if not avoided could result in equipment damage data loss performance dete...

Page 4: ...e 08 2020 04 20 This issue is the eighth official release 07 2019 11 15 This issue is the seventh official release 06 2019 08 23 Added the support for Cascade Lake processors 05 2018 11 30 This issue is the fifth official release 04 2018 07 23 This issue is the fourth official release 03 2018 05 08 This issue is the third official release 02 2018 02 24 This issue is the second official release 01 ...

Page 5: ...r 22 5 4 2 Memory Subsystem Architecture 24 5 4 3 Memory Compatibility 25 5 4 4 Memory Installation Guidelines 27 5 4 5 Memory Installation Positions 27 5 4 6 Memory Protection Technologies 29 5 5 Storage 30 5 5 1 Drive Configurations 30 5 5 2 Drive Numbering 30 5 5 3 Drive Indicators 31 5 5 4 RAID Controller Card 32 5 6 I O Expansion 33 5 6 1 PCIe Cards 33 5 6 2 PCIe Slots 33 5 6 3 PCIe Slot Desc...

Page 6: ...Safety Instructions 51 8 2 Maintenance and Warranty 54 9 System Management 55 10 Certifications 57 A Appendix 59 A 1 Product SN 59 A 2 Operating Temperature Limitations 60 A 3 RAS Features 61 A 4 Sensor List 64 B Glossary 70 B 1 A E 70 B 2 F J 71 B 3 K O 71 B 4 P T 71 B 5 U Z 72 C Acronyms and Abbreviations 73 C 1 A E 73 C 2 F J 74 C 3 K O 75 C 4 P T 76 C 5 U Z 78 Huawei FusionServer Pro 2488 V5 S...

Page 7: ... V5 is ideal for applications such as databases cloud computing virtualization and in memory computing The 2488 V5 is a secure highly expandable server delivering high performance computing large storage capacity and low power consumption It is easy to deploy and manage and supports virtualization Figure 1 1 2488 V5 Huawei FusionServer Pro 2488 V5 Server Technical White Paper 1 Overview Issue 11 2...

Page 8: ... processor core to run up to two threads improving parallel computation capability The hardware assisted Intel Virtualization Technology Intel VT allows operating system OS vendors to better use hardware to address virtualization workloads With Intel Advanced Vector Extensions 512 AVX 512 applications can pack 32 double precision and 64 single precision floating point operations per second in a cl...

Page 9: ... against power failures The server provides simplified O M and efficient troubleshooting through the UID HLY indicators on the front panel fault diagnosis LED touch LCD diagnosis panel and iBMC web interface The SSDs offer better reliability than HDDs ensuring continued system performance The built in iBMC monitors system parameters in real time triggers alarms and performs recovery actions to min...

Page 10: ...t Configuring IPv4 addresses IPv4 address subnet mask and gateway and IPv6 addresses IPv6 address prefix length and gateway for this port Energy Efficiency The 80 Plus Platinum power supply units PSUs of multiple power ratings provide 94 power efficiency at 50 load Efficient voltage regulator down VRD power supplies for boards minimize the energy loss from DC DC power conversion Area based Proport...

Page 11: ...SU backplane 5 Cable organizer 6 Chassis 7 Air duct 8 Drive backplane 9 Fan module brackets 10 Drives 11 DVD drive or LCD 12 Fan modules 13 VGA board 14 Processors 15 Mainboard 16 TPM TCM Huawei FusionServer Pro 2488 V5 Server Technical White Paper 3 Physical Structure Issue 11 2020 09 03 Copyright Huawei Technologies Co Ltd 5 ...

Page 12: ...17 DIMMs 18 Heat sinks Huawei FusionServer Pro 2488 V5 Server Technical White Paper 3 Physical Structure Issue 11 2020 09 03 Copyright Huawei Technologies Co Ltd 6 ...

Page 13: ...1 2488 V5 logical structure The server supports two or four Intel Xeon Scalable processors Huawei FusionServer Pro 2488 V5 Server Technical White Paper 4 Logical Structure Issue 11 2020 09 03 Copyright Huawei Technologies Co Ltd 7 ...

Page 14: ...dard PCIe 3 0 slots of various specifications The server provides low speed I O ports such as the VGA port USB 3 0 ports and serial ports RJ45 The server provides four LOM ports including two 10GE optical ports and two GE electrical ports Huawei FusionServer Pro 2488 V5 Server Technical White Paper 4 Logical Structure Issue 11 2020 09 03 Copyright Huawei Technologies Co Ltd 8 ...

Page 15: ... 5 6 I O Expansion 5 7 PSUs 5 8 Fans 5 9 LCD 5 10 Boards 5 1 Front Panel 5 1 1 Appearance 8 x 2 5 SAS SATA drive configuration Figure 5 1 Front view Huawei FusionServer Pro 2488 V5 Server Technical White Paper 5 Hardware Description Issue 11 2020 09 03 Copyright Huawei Technologies Co Ltd 9 ...

Page 16: ... 2 Slide out label plate with an SN label 25 x 2 5 SAS SATA drive configuration Figure 5 3 Front view 1 Drives 2 Slide out label plate with an SN label 5 1 2 Indicators and Buttons Positions 8 x 2 5 SAS SATA drive configuration Huawei FusionServer Pro 2488 V5 Server Technical White Paper 5 Hardware Description Issue 11 2020 09 03 Copyright Huawei Technologies Co Ltd 10 ...

Page 17: ...guration Figure 5 5 Indicators and buttons on the front panel 1 LOM port 1 connection status indicator 2 LOM port 2 connection status indicator 3 LOM port 3 connection status indicator 4 LOM port 4 connection status indicator 5 Fault diagnosis LED 6 Health status indicator 7 UID button indicator 8 Power button indicator 9 NMI button Note There are eight NVMe drives four NVMe drives on the left and...

Page 18: ...ton indicator 8 Power button indicator Indicator and Button Description Table 5 1 Indicators and buttons on the front panel Silkscreen Indicator Button Description Fault diagnosis LED The device is operating normally Fault code A component is faulty For details about error codes see FusionServer Pro Rack Server iBMC Alarm Handling Huawei FusionServer Pro 2488 V5 Server Technical White Paper 5 Hard...

Page 19: ...ice UID indicator Off The device is not being located Blinking blue The device has been located and is distinguished from other devices that have also been located Steady blue The device is being located UID button You can turn on or off the UID indicator by pressing the UID button on the panel or by using the iBMC CLI or WebUI You can press this button to turn on or off the UID indicator You can ...

Page 20: ...us indicator Each indicator shows the connection status of an Ethernet LOM port Off The network port is not in use or has failed Steady green The network port is properly connected NOTE The indicators correspond to two 10GE and two GE network ports on the mainboard The LOM has a standby power supply and will not be powered off even if the service system is powered off As long as the LOM ports are ...

Page 21: ...ts on the front panel 1 USB 2 0 ports Port Description Table 5 2 Ports on the front panel Port Type QuantityNote Description VGA port DB15 1 Used to connect a display terminal such as a monitor or KVM USB port USB 2 0 2 Used to connect to a USB device Huawei FusionServer Pro 2488 V5 Server Technical White Paper 5 Hardware Description Issue 11 2020 09 03 Copyright Huawei Technologies Co Ltd 15 ...

Page 22: ...ber of ports varies depending on server configuration This table lists the maximum number of ports in different configurations 5 2 Rear Panel 5 2 1 Appearance Figure 5 10 Rear view 1 PCIe slot 1 2 PCIe slot 2 3 PCIe slot 3 4 PCIe slot 4 5 PCIe slot 5 6 PCIe slot 6 7 PSU 1 8 PSU 2 Huawei FusionServer Pro 2488 V5 Server Technical White Paper 5 Hardware Description Issue 11 2020 09 03 Copyright Huawe...

Page 23: ...t 4 4 Connection status indicator Data transmission status indicator for 10GE optical port 3 5 Data transmission rate indicator for 10GE optical port 4 6 Data transmission rate indicator for 10GE optical port 3 7 Data transmission status indicator for the management network port 8 Connection status indicator for the management network port 9 Health status indicator 10 UID indicator 11 PSU indicato...

Page 24: ... devices UID indicator The UID indicator helps identify and locate a device Off The device is not being located Blinking blue The device has been located and is differentiated from other devices that have also been located Steady blue The device is being located NOTE You can turn on or off the UID indicator by pressing the UID button or remotely running a command on the iBMC CLI Health status indi...

Page 25: ...ta transmission status indicator for a 10GE optical port Off The network port is not connected Blinking green Data is being transmitted Steady green The network port is properly connected Data transmission rate indicator for a 10GE optical port Off The network port is not connected or the data transmission rate is not 1 Gbit s or 10 Gbit s Steady green The data transmission rate is 1 Gbit s or 10 ...

Page 26: ...g You can also set it as the iBMC serial port by using the iBMC command NOTE The port uses 3 wire serial communication interface and the default baud rate is 115 200 bit s Management network port 1000BASE T 1 Used for server management NOTE The management network port is a GE port that supports 100 Mbit s and 1000 Mbit s auto negotiation USB port USB 3 0 2 Used to connect to a USB device NOTICE Be...

Page 27: ...ull duplex 1000M 10 100M Use Computing Product Compatibility Checker to obtain information about the cables and optical modules supported by the LOM ports The LOM ports support NC SI and PXE The LOM ports do not support forced rates The electrical LOM ports cannot be connected to power over Ethernet PoE devices such as a switch with PoE enabled Connecting a LOM port to a PoE device may cause link ...

Page 28: ... representative or use the Computing Product Compatibility Checker to determine the components to be used Figure 5 13 Processor positions 5 4 Memory 5 4 1 Memory Identifier You can determine the memory module properties based on the label attached to the memory module Huawei FusionServer Pro 2488 V5 Server Technical White Paper 5 Hardware Description Issue 11 2020 09 03 Copyright Huawei Technologi...

Page 29: ...uad rank 8R octal rank 3 Data width on the DRAM X4 4 bit X8 8 bit 4 Type of the memory interface PC3 DDR3 PC4 DDR4 5 Maximum memory speed 2133 MT S 2400 MT S 2666 MT S 2933 MT S 6 Column Access Strobe CAS latency P 15 T 17 7 DIMM type R RDIMM L LRDIMM Huawei FusionServer Pro 2488 V5 Server Technical White Paper 5 Hardware Description Issue 11 2020 09 03 Copyright Huawei Technologies Co Ltd 23 ...

Page 30: ...l Memory Slot CPU 1 A primary DIMM000 A A DIMM001 G B DIMM010 B C DIMM020 C D primary DIMM030 D D DIMM031 H E DIMM040 E F DIMM050 F CPU 2 A primary DIMM100 A A DIMM101 G B DIMM110 B C DIMM120 C D primary DIMM130 D D DIMM131 H E DIMM140 E F DIMM150 F CPU 3 A primary DIMM200 A A DIMM201 G B DIMM210 B C DIMM220 C D primary DIMM230 D D DIMM231 H E DIMM240 E F DIMM250 F Huawei FusionServer Pro 2488 V5 ...

Page 31: ...nd height cannot be used together Contact your local Huawei sales representative or use the Computing Product Compatibility Checker to determine the components to be used The memory can be used with Intel Xeon Scalable Skylake and Cascade Lake processors The maximum memory capacity supported varies depending on the processor model Skylake processors M processors 1 5 TB socket Other processors 768 ...

Page 32: ... 5 7 DDR4 memory specifications Parameter Specifications Maximum capacity per DDR4 DIMM GB 128 Rated speed MT s 2933 Operating voltage V 1 2 Maximum number of DDR4 DIMMs in a servera 32 Maximum DDR4 memory capacity of the server GB b 4096 Maximum operating speed MT s 1DPCc 2933d 2DPC 2666 a The maximum number of DDR4 DIMMs is based on four processor configuration The value is halved for a server w...

Page 33: ...upports two integrated memory controllers IMCs At least two channels of each IMC are used for installing DIMMs channels 1 and 2 or channels 1 2 and 3 The DIMMs installed must be identical in size and organization For a multi processor configuration each processor must have a valid memory mirroring configuration Memory scrubbing mode Comply with the general installation guidelines 5 4 5 Memory Inst...

Page 34: ...Figure 5 15 Memory slots Huawei FusionServer Pro 2488 V5 Server Technical White Paper 5 Hardware Description Issue 11 2020 09 03 Copyright Huawei Technologies Co Ltd 28 ...

Page 35: ...delines 4 processors 5 4 6 Memory Protection Technologies The following memory protection technologies are supported ECC Full mirroring Address range mirroring Huawei FusionServer Pro 2488 V5 Server Technical White Paper 5 Hardware Description Issue 11 2020 09 03 Copyright Huawei Technologies Co Ltd 29 ...

Page 36: ...AID controller card 24 x 2 5 16 x SAS SATA 8 x NVMe drive configuration 24 Slots 0 to 3 and slots 20 to 23 support only NVMe drives Slots 4 to 19 support only SAS SATA drives 1 x RAID controller card 2 x NVMe adapter 25 x 2 5 SAS SATA drive configuration 25 Slots 0 to 24 support only SAS SATA drives 1 x RAID controller card Contact your local Huawei sales representative or use the Computing Produc...

Page 37: ... 5 21 SAS SATA drive indicators Table 5 9 Description of SAS SATA drive indicators Activity Indicator Green Fault Indicator Yellow Description Steady on Off The drive is in position Blinking at 4 Hz Off Data is being read or written normally or data on the primary drive is being rebuilt Huawei FusionServer Pro 2488 V5 Server Technical White Paper 5 Hardware Description Issue 11 2020 09 03 Copyrigh...

Page 38: ...Indicator Yellow Description Off Off The NVMe drive cannot be detected Steady on Off The NVMe drive is working properly Blinking at 2 Hz Off Data is being read from or written to the NVMe drive Off Blinking at 2 Hz The NVMe drive is being located or hot swapped Off Blinking at 0 5 Hz The hot removal process is complete and the NVMe drive is removable Steady on Off Steady on The NVMe drive is fault...

Page 39: ... Contact your local Huawei sales representative or use the Computing Product Compatibility Checker to determine the components to be used 5 6 2 PCIe Slots PCIe Slots Figure 5 23 PCIe slots Slots 1 to 3 and 5 to 9 are provided by the mainboard Slot 4 is provided by the PCIe riser module 5 6 3 PCIe Slot Description NOTE The PCIe slots mapping to a vacant CPU socket are unavailable Huawei FusionServe...

Page 40: ...he server is fully configured with PCIe devices The values may vary if the server is not fully configured with PCIe devices or if a PCIe card with a PCI bridge is configured The PCIe x16 slots are backward compatible with PCIe x8 PCIe x4 and PCIe x1 cards The PCIe cards are not forward compatible That is the PCIe slot width cannot be smaller than the PCIe card link width The full height half lengt...

Page 41: ...wo 1500 W Platinum AC PSUs When the input voltage is from 100 V AC to 132 V AC the output power drops to 1000 W Two 1500 W AC Platinum PSUs can serve as 1700 W PSUs Figure 5 24 PSU positions 5 8 Fans The server supports four fan modules The fan modules are hot swappable The server tolerates failure of a single fan The fan speed can be adjusted The same model of fan modules must be used in a server...

Page 42: ...t on the server The LCD and the server iBMC form an LCD subsystem The LCD directly obtains device information from the iBMC The LCD subsystem does not store device data but allows users to query device status and alarms Figure 5 26 LCD subsystem working principle Huawei FusionServer Pro 2488 V5 Server Technical White Paper 5 Hardware Description Issue 11 2020 09 03 Copyright Huawei Technologies Co...

Page 43: ...isplays the IP address and MAC address of the iBMC management network port MAC addresses of host LOM ports device SNs asset information and firmware version Setting Sets the IP address of the iBMC management network port For details about how to use the LCD see 2488 V5 Server V100R005 LCD User Guide 5 10 Boards Huawei FusionServer Pro 2488 V5 Server Technical White Paper 5 Hardware Description Iss...

Page 44: ...responding to CPU 3 5 PCIe x8 slot 5 corresponding to CPU 3 6 PCIe riser slots corresponding to CPU 2 7 BMC GE port J142 8 Jumper J93 a 9 VGA connector VGA CONN J169 10 Serial port RJ45 CONN J171 Huawei FusionServer Pro 2488 V5 Server Technical White Paper 5 Hardware Description Issue 11 2020 09 03 Copyright Huawei Technologies Co Ltd 38 ...

Page 45: ...tor HDD BP J133 29 System battery U4042 30 PCIe x16 slot 9 corresponding to CPU 3 31 PCIe x8 slot 8 corresponding to CPU 3 32 Left mounting ear connector LEFT EAR CONN BOARD J115 33 Drive backplane power connector BP PWR J128 34 PSU backplane connectors J209 J210 J208 35 VROC key port J144 c a The BMC_SER_MANUAL pin is used for changing the connection direction of the physical serial port The CLEA...

Page 46: ... 30 24 x 2 5 16 x SAS SATA 8 x NVMe drive backplane 1 NVMe PORT B_N2 J26 2 NVMe PORT B_N0 J24 3 NVMe PORT B_N1 J25 4 SAS cable connector PORT C_0 J28 5 SAS cable connector PORT C_1 J29 6 NVMe PORT A_N1 J21 7 NVMe PORT A_N0 J20 8 NVMe PORT A_N2 J22 9 Backplane signal cable connector J1 10 Backplane power connector J3 Huawei FusionServer Pro 2488 V5 Server Technical White Paper 5 Hardware Descriptio...

Page 47: ...rive backplane 1 SAS cable connector Port A J28 2 SAS cable connector Port B J29 3 SAS cable connector J31 4 Backplane signal cable connector J1 5 Power connector J24 Huawei FusionServer Pro 2488 V5 Server Technical White Paper 5 Hardware Description Issue 11 2020 09 03 Copyright Huawei Technologies Co Ltd 41 ...

Page 48: ...y controller and six memory channels Built in PCIe controller supporting PCIe 3 0 and 48 lanes per processor Three UPI buses between processors providing up to 10 4GT s transmission per channel Up to 28 cores 2 7 GHz Max 3 8 GHz four cores Min 1 375 MB L3 cache per core Max 205 W TDP NOTE The preceding information is for reference only Use the Computing Product Compatibility Checker to obtain spec...

Page 49: ... different types RDIMM and LRDIMM and specifications capacity bit width rank and height cannot be used together NOTE The preceding information is for reference only Use the Computing Product Compatibility Checker to obtain specific information Huawei FusionServer Pro 2488 V5 Server Technical White Paper 6 Product Specifications Issue 11 2020 09 03 Copyright Huawei Technologies Co Ltd 43 ...

Page 50: ...033696 Configure syslog For details see https kb vmware com s article 2003322 The M 2 SSD cannot be used to store data due to poor endurance In write intensive applications the M 2 SSD will wear out in a short time Use enterprise level high endurance HE SSDs or HDDs for data storage The M 2 SSD is not recommended for write intensive service software due to poor endurance Do not use the M 2 SSD as ...

Page 51: ...communication failure or even damage the NIC I O expansion 9 PCIe 3 0 slots Three slots for built in cards and six for external cards For details see 5 6 2 PCIe Slots and 5 6 3 PCIe Slot Description Support Huawei proprietary PCIe SSD cards to bolster I O performance for applications such as searching caching and download services NOTE The preceding information is for reference only Use the Comput...

Page 52: ...USB storage media Video card An SM750 video chip with 32 MB display memory is integrated on the mainboard The maximum display resolution is 1920 x 1200 at 60 Hz with 16 M colors NOTE The integrated video card can provide the maximum display resolution 1920 x 1200 only after the video card driver matching the operating system version is installed Otherwise only the default resolution supported by t...

Page 53: ...storage temperature 72 hours 21 C to 27 C 69 8 F to 80 6 F Maximum temperature change rate 20 C h 36 F h NOTE The highest operating temperature varies depending on the server configuration For details see A 2 Operating Temperature Limitations Relative humidity RH non condensing Operating humidity 8 to 90 Storage humidity 72 hours 5 to 95 Long term storage humidity 72 hours 30 to 69 Maximum change ...

Page 54: ...uirements of the ANSI ISA 71 04 2013 standard on gaseous corrosion Silver corrosion rate test 200 Å month Particle contaminant The equipment room environment meets the requirements of ISO 14664 1 Class 8 There is no explosive conductive magnetic or corrosive dust in the equipment room NOTE It is recommended that the particulate pollution in the equipment room be monitored by a professional agency ...

Page 55: ...48 5 mm 21 40 in to 33 41 in between the front and rear mounting bars Ball bearing rail kit applies to cabinets with a distance of 610 mm to 914 mm 24 02 in to 35 98 in between the front and rear mounting bars Weight in full configuration Maximum net weight Server with 8 x 2 5 drives 27 kg 59 54 lb Server with 25 x 2 5 drives 30 kg 66 15 lb Packaging materials 5 kg 11 03 lb Power consumption The p...

Page 56: ...ic software and hardware may cause performance inconsistency between the application layer and test software layer If the customer has requirements on the performance of specific application software contact Huawei sales personnel to apply for POC tests in the pre sales phase to determine detailed software and hardware configurations If the customer has requirements on hardware performance consist...

Page 57: ...g a forklift Take protective measures if a Class A product is used in residential areas as it is likely to cause radio interference Personal Safety Only personnel certified or authorized by Huawei are allowed to install the hardware Stop any operation that may cause personal injury or equipment damage report the problem to a project supervisor immediately and take protective measures Do not operat...

Page 58: ...ure 8 2 Conductive objects to be removed Figure 8 3 shows how to wear an ESD wrist strap a Secure the ESD wrist strap around your wrist b Fasten the strap buckle and ensure that the ESD wrist strap is in contact with your skin c Insert the ground terminal attached to the ESD wrist strap into the jack on the grounded rack or chassis Huawei FusionServer Pro 2488 V5 Server Technical White Paper 8 Saf...

Page 59: ...he handles of the installed modules such as the PSUs fan modules drives and the mainboard Handle the equipment with care Exercise caution when using tools that could cause personal injury If the device is configured with active and standby PSUs connect power cables of active and standby PSUs to different power distribution units PDUs to ensure reliable system operating Properly ground a device bef...

Page 60: ...y a number of organizations Table 8 1 Maximum weight one person is permitted to carry Organization Weight kg lb European Committee for Standardization CEN 25 55 13 International Organization for Standardization ISO 25 55 13 National Institute for Occupational Safety and Health NIOSH 23 50 72 Health and Safety Executive HSE 25 55 13 General Administration of Quality Supervision Inspection and Quara...

Page 61: ...and text console redirection Remote virtual media IPMI SNMP Common information model CIM Redfish Browser based login Specifications Table 9 1 iBMC specifications Feature Description Management interface Integrates with any standard management system through the following interfaces or protocols IPMI CLI HTTPS SNMP Redfish Fault detection Detects and accurately locates faults in hardware for exampl...

Page 62: ...erations Fault reproduction Reproduces faults to help diagnose them quickly Screen snapshots and screen videos Allows users to view screenshots and videos without login facilitating routine preventive maintenance inspection PMI Black Box Allows users to enable or disable the black box function and download black box data DNS LDAP Supports domain management and directory services significantly simp...

Page 63: ... A11 2017 EMC EN 55032 2012 AC 2013 CISPR 32 2012 EN 55032 2015 AC 2016 CISPR 32 2015 EN 55035 2017 CISPR 35 2016 ETSI EN 300 386 V1 6 1 2012 ETSI EN 300 386 V2 1 1 2016 EN 61000 3 2 2014 EN 61000 3 3 2013 RoHS 2011 65 EU EU 2015 863 EN 50581 2012 ErP 2009 125 EC ErP Directive Commission Regulation EU 2019 424 Huawei FusionServer Pro 2488 V5 Server Technical White Paper 10 Certifications Issue 11 ...

Page 64: ... 1 2005 2nd Edition A1 2009 EN 60950 1 2006 A11 2009 A1 2010 A12 2011 Nigeria SONCAP IEC 60950 1 2005 2nd Edition A1 2009 EN 60950 1 2006 A11 2009 A1 2010 A12 2011 Kuwait Kucas IEC 60950 1 2005 2nd Edition A1 2009 EN 60950 1 2006 A11 2009 A1 2010 A12 2011 Huawei FusionServer Pro 2488 V5 Server Technical White Paper 10 Certifications Issue 11 2020 09 03 Copyright Huawei Technologies Co Ltd 58 ...

Page 65: ...ple Table A 1 SN description Callout No Description 1 SN ID two characters which is 21 2 Material identification code 8 characters that is the processing code 3 Vendor code two characters 10 indicates Huawei and other values indicate outsourcing vendors Huawei FusionServer Pro 2488 V5 Server Technical White Paper A Appendix Issue 11 2020 09 03 Copyright Huawei Technologies Co Ltd 59 ...

Page 66: ...s A to C indicate October to December respectively 5 Sequence number six characters 6 RoHS compliance one character Y indicates RoHS compliant 7 Internal model that is product name A 2 Operating Temperature Limitations Table A 2 Operating temperature limitations Configuratio n Max 30 C 86 F Max 35 C 95 F Max 40 C 104 F Max 45 C 113 F 8 x 2 5 SAS SATA drive configuration All options supported All o...

Page 67: ...pported processors of up to 165 W Options not supported NVMe SSD cards in slots 1 to 6 GPU cards Not supported NOTE If a single fan is faulty the maximum operating temperature is 5 C 9 F lower than the rated value A 3 RAS Features The server supports a variety of Reliability Availability and Serviceability RAS features You can configure these features for better RAS For details about how to config...

Page 68: ...ction Provides a single device multi bit error correction capability to improve memory reliability Device Tagging Degrades and rectifies DIMM device faults to improve DIMM availability Data Scrambling Optimizes data stream distribution and reduces the error possibility to improve the reliability of data streams in the memory and the capability to detect address errors PCIe PCIe Advanced Error Repo...

Page 69: ... features Machine Check Architecture Provides software recovery for uncorrectable errors to improve system availability eMCA Gen2 Improves system availability OOB access to MCA registers The OBB system accesses MCA registers by using the Platform Environment Control Interface PECI If a fatal error occurs in the system the out of band system collects onsite data to facilitate fault analysis and loc...

Page 70: ...TS CPU DTS value CpuN Margin CPU1 Margin temperature CPUN Prochot CPU Prochot CPUN VDDQ Temp CPU VDDQ temperature CPU 1 Components in positions U4333 and U4339 on the mainboard CPU 2 Components in positions U4343 and U4347 on the mainboard CPU 3 Components in positions U4351 and U4355 on the mainboard CPU 4 Components in positions U4359 and U4363 on the mainboard N indicates the CPU number The val...

Page 71: ...Fan speed sensor Fan module N indicates the fan module number The value ranges from 1 to 4 FANN R Speed Power Server input power Total PSU power PowerN PSU input power PSU N indicates the PSU number The value is 1 or 2 CPUN Status CPU status CPU N indicates the CPU number The value ranges from 1 to 4 CPUN Memory DIMM status DIMM corresponding to the CPU N indicates the DIMM number The value ranges...

Page 72: ... 2 PCH Status PCH chip fault diagnosis health status Component in position U4014 on the mainboard LCD Presence LCD presence LCD LCD Status LCD health status PSN Redundancy Redundancy failure due to PSU removal PSU N indicates the PSU number The value is 1 or 2 BMC Boot Up BMC startup events N A N indicates the number of the component SEL Status SEL full or clearing events Op Log Full Operation log...

Page 73: ...r soft start CPU2 CPU3 SYS 12V_3 Mainboard 12 0 V voltage the third output 12 V voltage detection for soft start CPU4 fan module SYS 12V_4 Mainboard 12 0 V voltage the fourth output 12 V output voltage detection for soft start drive backplane module Standby 5V Mainboard standby 5 0 V voltage Standby 3 3V Mainboard standby 3 3 V voltage Standby 1 8V Mainboard standby 1 8 V voltage Standby 1 5V Main...

Page 74: ... system restart Boot Error Boot error Watchdog2 Watchdog Mngmnt Health Management subsystem health status Riser1 Card Entity presence PCIe RAIDN Temp LSI SAS3508 RAID controller card temperature PCIe RAIDN Temp Avago SAS3004 RAID controller card temperature M2 Temp PCIeN Maximum temperature of all M 2 drives of the RAID controller card PCIe Status PCIe status PwrOn TimeOut Power on timeout PwrCap ...

Page 75: ...1 2 3 4 CPU UPI link fault diagnosis health status System Notice Hot restart notice Collect error information for the fault diagnosis program System Error System suspension or restart Check the background logs Huawei FusionServer Pro 2488 V5 Server Technical White Paper A Appendix Issue 11 2020 09 03 Copyright Huawei Technologies Co Ltd 69 ...

Page 76: ...ge the objects E ejector lever A part on the panel of a device used to facilitate installation or removal of the device Ethernet A baseband local area network LAN architecture developed by Xerox Corporation by partnering with Intel and DEC Ethernet uses the Carrier Sense Multiple Access Collision Detection CSMA CD access method and allows data transfer over various cables at 10 Mbit s The Ethernet...

Page 77: ...erver It seals the front and rear of the chassis to ensure optimal ventilation and electromagnetic compatibility EMC Peripheral Component Interconnect Express PCIe A computer bus PCI which uses the existing PCI programming concepts and communication standards but builds a faster serial communication system Intel is the main sponsor for PCIe PCIe is used only for internal interconnection A PCI syst...

Page 78: ...pecial computer that provides services for clients over a network system event log SEL A non volatile area and interfaces used to store system events for later fault diagnosis and system recovery B 5 U Z U U A unit defined in International Electrotechnical Commission IEC 60297 1 to measure the height of a cabinet or chassis 1 U 44 45 mm UltraPath Interconnect UPI A point to point processor interco...

Page 79: ... Vector Extensions B BBU backup battery unit BIOS Basic Input Output System BMC baseboard management controller C CD calendar day CE Conformite Europeenne CIM Common Information Model CLI command line interface Huawei FusionServer Pro 2488 V5 Server Technical White Paper C Acronyms and Abbreviations Issue 11 2020 09 03 Copyright Huawei Technologies Co Ltd 73 ...

Page 80: ...an Computer Manufacturer Association EDB Execute Disable Bit EN European Efficiency ERP enterprise resource planning ETS European Telecommunication Standards C 2 F J F FB DIMM Fully Buffered DIMM FC Fiber Channel FCC Federal Communications Commission FCoE Fibre Channel over Ethernet FTP File Transfer Protocol G GE Gigabit Ethernet Huawei FusionServer Pro 2488 V5 Server Technical White Paper C Acro...

Page 81: ...ternet Data Center IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers IGMP Internet Group Message Protocol IOPS input output operations per second IP Internet Protocol IPC intelligent power capability IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface C 3 K O K KVM keyboard video and mouse Huawei FusionServer Pr...

Page 82: ... Controller Sideband Interface C 4 P T P PCIe Peripheral Component Interconnect Express PDU power distribution unit PHY physical layer PMBUS power management bus POK power OK PWM pulse width modulation PXE Preboot Execution Environment Q QPI Quick Path Interconnect Huawei FusionServer Pro 2488 V5 Server Technical White Paper C Acronyms and Abbreviations Issue 11 2020 09 03 Copyright Huawei Technol...

Page 83: ... single device data correction SERDES serializer deserializer SGMII serial gigabit media independent interface SMI serial management interface SMTP Simple Mail Transfer Protocol SNMP Simple Network Management Protocol SOL serial over LAN SONCAP Standards Organization of Nigeria Conformity Assessment Program SSD solid state drive SSE Streaming SIMD Extensions T TACH tachometer signal TBT Turbo Boos...

Page 84: ...e Interface UID unit identification light UL Underwriter Laboratories Inc USB Universal Serial Bus V VCCI Voluntary Control Council for Interference by Information Technology Equipment VGA Video Graphics Array VLAN virtual local area network VRD voltage regulator down W WEEE waste electrical and electronic equipment WSMAN Web Service Management Huawei FusionServer Pro 2488 V5 Server Technical Whit...

Reviews: