Caution -
Ensure that all power is removed from the server before removing or installing
the motherboard assembly. You must disconnect the power cables from the server before
performing these procedures.
Caution -
These procedures require that you handle components that are sensitive to ESD. This
sensitivity can cause the component to fail. To avoid damage, ensure that you follow antistatic
practices as described in
.
Replacing the SP is a cold-service procedure that must be performed by qualified service
personnel. The server must be completely powered down before performing this procedure.
See
“Component Service Categories” on page 57
for more information about this category of
service procedures.
Before You Begin
The amber SP OK/Fault LED on the front panel will be lit when an SP fault is detected.
1.
If possible, back up the Oracle ILOM configuration before removing the SP.
After you replace the SP, restoring the SP configuration will be easier if you previously
saved the configuration using the Oracle ILOM backup utility. Refer to the Oracle ILOM
documentation for instructions on backing up and restoring the Oracle ILOM configuration.
To retain the same version of the system firmware with the new SP, note the current version
before removing the SP.
2.
Prepare for servicing.
a.
Attach an antistatic wrist strap.
b.
Power off the server and unplug power cords from the power supplies.
See
“Removing Power From the Server” on page 58
.
c.
Remove the server from the rack.
See
“Remove the Server From the Rack” on page 66
.
d.
Remove the top cover.
See
“Remove the Top Cover” on page 67
3.
Locate the SP.
130
SPARC T5-2 Server Service Manual • February 2017
Summary of Contents for SPARC T5-2
Page 1: ...SPARC T5 2 Server Service Manual Part No E28856 13 February 2017 ...
Page 2: ......
Page 10: ...10 SPARC T5 2 Server Service Manual February 2017 ...
Page 12: ...12 SPARC T5 2 Server Service Manual February 2017 ...
Page 52: ...52 SPARC T5 2 Server Service Manual February 2017 ...
Page 96: ...96 SPARC T5 2 Server Service Manual February 2017 ...
Page 112: ...112 SPARC T5 2 Server Service Manual February 2017 ...
Page 120: ...120 SPARC T5 2 Server Service Manual February 2017 ...
Page 140: ...140 SPARC T5 2 Server Service Manual February 2017 ...
Page 156: ...156 SPARC T5 2 Server Service Manual February 2017 ...
Page 162: ...162 SPARC T5 2 Server Service Manual February 2017 ...
Page 174: ...174 SPARC T5 2 Server Service Manual February 2017 ...
Page 180: ...180 SPARC T5 2 Server Service Manual February 2017 ...
Page 185: ...Index SP 133 video connector location of 13 viewing message log files 50 185 ...
Page 186: ...186 SPARC T5 2 Server Service Manual February 2017 ...