Coin Cell Battery Replacement
DANGER:
The inside of the terminal contains high-voltage circuitry; ONLY
certified technicians should be permitted access to the console.
ATTENTION: Electrostatic Sensitive Device -
To prevent damage to the
electronic components in this device from electrostatic discharge, obey the
precautions below when you do this procedure. Electrostatic discharge damage
can also cause a security breach in a component.
Use an ESD Field Service Kit with wrist strap, dissipative mat and grounding cord
when possible.
Do not touch the circuitry if you are not grounded correctly.
To remove the battery, pull the locking clip to the left to disengage the lock.
Carefully lift the battery out of its socket.
Put the new battery in the empty socket, push down on the battery and pull the locking clip to the right to lock
the battery in position.
DX Fleet Option Installation
WARNING:
To prevent an electrical shock hazard, de-energize the Terminal
before you do this procedure! Push the Terminal rocker switch on the Power
Supply to the
O
(Off) position.
Doc. No.: M1010 Rev.: 10
Page 74 of 98
Summary of Contents for Petro Vend 200 M1010