I/O Settings
96
ZG User’s Manual
Setting the Number of Digits Past the Decimal Point
Set the number of digits past the decimal point of the measurement value to output to the
Real-time Parallel Output Unit.
FUN mode-[I/O]-[RPD]-[DIGIT]
Setting I/O Conditions
Switching Bank Data
Set from where switching of banks is to be instructed.
FUN mode-[I/O]-[I/O LINE]-[BANK]
Setting the Measurement Trigger
Set the measurement timing method. The default setting is [DISABLE] (continuous
measurement).
FUN mode-[I/O]-[I/O LINE]-[TRIGGER]
Setting value
Description
5, 4, 3, 2, 1
Sets the number of output digits past the decimal point.
(default value: 3)
Setting value
Description
MENU
Bank switching is performed by operating the control keys. (default
value)
EXT IN
Bank switching is performed from the external input wire.
Setting value
Description
ENABLE
The trigger is used as the measurement timing.
DISABLE
The trigger is not used and measurement is performed
continuously. (default value)