Mounting and Connecting Devices
26
ZG User’s Manual
Mounting the ZG-WDS8T
Fix by mounting screws making sure that the distance between the Sensor and
measurement target is matched.
Mounting method
Fasten the Sensor onto the mounting base
with M4 screws.
Tightening torque: 1.2 N•m
For details on the positions of screw holes,
check the external dimensions in “Chapter 5
APPENDICES.”
External dimensions p.164
Mounting position
Mount the Sensor according to the following distances and angle.
The default mounting state of the Sensor is for diffuse reflection measurement. To set the
Sensor for regular reflection measurement, change the Sensor mounting setting.
Setting the Sensor Installation Status p.100
Important
Mounting for diffuse reflection
measurement
Emission axis
Reception axis
50 mm
30°
Measurement target
Mounting for regular reflection
measurement
Emission axis
Reception axis
44 mm
Measurement target
15°
N
ot
e