Measurement Settings
77
ZG User’s Manual
3
FUNCTION SETTINGS
Setting the Measurement Region
Extremely bright parts or areas other than the measurement target sometimes cause the
sensitivity adjustment to become unstable.
If this happens, measurement can be made stable by adjusting the region to restrict the
area to be adjusted for sensitivity.
FUN mode-[MEAS]-[IMAGE]-[REGION]
1
Select [CHANGE].
2
Adjust the top left of the desired
measurement area by the
↑
,
↓
,
←
and
→
keys, and press the SET
key.
C
C
A
B
B
A: This region is targeted for both sensitivity adjustment and measurement.
B: This region is outside the sensitivity adjustment target area, and is targeted
for measurement only.
C: This region is outside the measurement target area, and the measurement
image is deleted.
Measurement region