Mounting and Connecting Devices
23
ZG User’s Manual
1
BEFORE USE
Measurement range
< Mounting for diffuse reflection measurement >
The beam diameter and measurement range (width) between the NEAR/FAR ends are nominal
values, and are not to be used as guaranteed values.
Measurement
center distance
Measurement range
(height)
Measurement
range (width)
Beam diameter
210 mm
±30 mm
NEAR end: 63 mm
300 µm
CENTER:
70 mm
120 µm
FAR end:
79 mm
300 µm
NE
AR
end
+
30
mm
C
ENTE
R
0
mm
F
AR
end
-
30
mm
Measurement
center
d
i
stance
210
mm
Spread
ang
l
e
10
°
Ang
l
e
of
i
ntersect
i
on
19°
:
Measurement
range
: I
rrad
i
at
i
on
range
63
mm
70
mm
79
mm
Measurement
range
(w
i
dth)
Beam
d
i
ameter
Important