Measurement Settings
61
ZG User’s Manual
3
FUNCTION SETTINGS
Step
Measures the step from the reference plane.
• When there is one reference plane, select “2-pt step”.
• When there are two reference planes, select “3-pt step”.
< 2-pt step >
To measure a protrusion (+ direction) taking the base as the reference plane:
To measure an indentation (- direction) taking the top surface as the reference plane:
How to adjust the region p.66
Icon
Description
Average
Measures the step between the
average values of P1 and P2.
Peak
Measures the step between the
average value of P1 and the
maximum value of P2.
Icon
Description
Average
Measures the step between the
average values of P1 and P2.
Bottom
Measures the step between the
average value of P1 and the
minimum value of P2.
2-pt step
Step
Step
3-pt step
Step
P2 (average)
P1 (average)
Step
P2 (peak)
P1 (average)
Step
P1 (average)
P2 (average)
Step
P1 (average)
P2 (bottom)
Enclose the desired
measurement area.
Region is automatically set.
→
Check/adjustment
Illustration of automatic setting
Center line that divides the top and
bottom of the step
P1
P2
(reference)
(step=P2-P1)
Summary of Contents for ZG -
Page 12: ...10 ZG User s Manual MEMO ...
Page 44: ...Overview of Settings and Measurement 42 ZG User s Manual MEMO ...
Page 60: ...Functions Operations Used during Operation RUN Mode 58 ZG User s Manual MEMO ...
Page 110: ...System Settings 108 ZG User s Manual MEMO ...
Page 156: ...Serial Communication 154 ZG User s Manual MEMO ...
Page 206: ...204 ZG User s Manual MEMO ...
Page 207: ...205 ZG User s Manual 5 APPENDICES MEMO ...
Page 208: ...206 ZG User s Manual MEMO ...