7
.
EtherNet/IP Connection Procedure
59
4
The normal performance of tag data
links can be confirmed through the
status information in the Monitor
Device Dialog Box of Network
Configurator.
Right-click Controller (Node 1) in the
Network Configuration Pane and
select
Monitor
.
5
The Monitor Device Dialog Box is
displayed.
Check that the following check
boxes are selected on the Status 1
Tab Page.
- On-Line
- All Tag Data Link
- Tag Data Link
- Ethernet Link Status
Check that the target node status is
displayed as shown on the right.
Click
Close
.
6
Select
Disconnect
from the
Network Menu.
7
Check that the color of the network
connection icon changes to grey on
the
EtherNet/IP_1
Tab of the Network
Configuration Pane.
*It indicates that Network
Configurator and Controller are
offline.
Number: Node number