Window Components
Section 1-3
26
reopened.
Automatically Show Active Step in Monitoring Mode (Default: Checked)
Check the checkbox to have SFC diagram editor program view automatically updated
to track the active step, while debugging or editing online.
Automatically Select Active Step in Monitoring Mode (Default: Checked)
Displays the active step’s action program. This function is effective when the action is
hidden.
Snap to Grid (Default: Not checked)
Check the checkbox to align SFC elements to the grid when drag-and-dropped.
Grid Width
Use the slider to adjust the grid size.
Default Settings for SFC Elements
Changes to the options are for newly added elements inserted into the SFC Editor only.
Existing elements keep the previous settings.
SFC elements are labeled using the specified text string and an automatically assigned
number.
•
Step Prefix (Display name)
•
Transition Prefix (Display name)
•
Action Body Prefix (Display name)
•
Transition Body Prefix (Display name)
•
Subchart Prefix (Display name)
•
Element Width (Display width)
Note: This option setting is effective only on elements that are newly added to the SFC chart.
The setting has no effect on elements that were already added.inserted into the SFC
Editor only.
Note: Reserved words for addresses cannot be used as display names.
(Example: S, ST, T, TN, A, AC, etc.)
Use Extended SFC Settings
When this option is selected, the following advanced settings can be used.
Enabling/Disabling the SFC Program’s Final Scan:
The
Apply Final Scan Logic
Option can be selected in the General Tab of the SFC
program’s Property Dialog Box.
Option selected: Final scan execution is enabled for that entire SFC program.
Option not selected: Final scan execution is disabled for that entire SFC program.
Note:
For details on the final scan function, refer to
1-5-2 Action Program Precautions
.
Summary of Contents for SYSMAC CX-Programmer 8.1
Page 1: ...Operation Manual SFC Programming SYSMAC WS02 CXPC1 V8 CX Programmer Ver 8 1 Cat No W469 E1 04...
Page 2: ...ii CX Programmer Ver 8 1 WS02 CXPC1 V8 Operation Manual SFC Programming Revised February 2009...
Page 16: ......
Page 56: ...Precautions When Creating SFC Programs Section 1 5 40...
Page 118: ...Monitoring Section 4 5 102...
Page 150: ...Index 134...
Page 152: ...Revision History 136...
Page 153: ......
Page 154: ......