Specifications for Step Control Instructions
Appendix A
120
A-2
READ SET TIMER (TSR)/SET STEP TIMER (TSW)
TSR Instruction
Outline
Read the present value of the Step Timer.
Symbol
TSR
S
D
S: Step Timer
D: First word to store the Step Timer’s present value
Description
The present value of the Step Time specified by S is stored starting at D.
Variations
Executed Each Cycle for ON
Condition
TSR
Variations
Executed Once for Upward
Differentiation
@TSR
Immediate Refreshing Specification
None
Applicable Program Areas
Area
Function
block
definitions
Block
program
areas
Step
program
areas
Subroutines Interrupt
task
programs
Usage
OK OK
OK OK
OK
Operand Specifications
Area
S
D
CIO Area (e.g., I/O bits)
CIO 0000 to CIO
6143
Work Area
W000 to W511
Holding Bit Area
Step Timer
H000 to H511
Auxiliary Bit Area
A448 to A959
DM Area
D00000 to D32767
EM Area
E00000 to E32767
En_00000 to
En_32767
(n = 0 to C)
Constants
#0000 to #FFFF
(binary data)
Condition Flags
Name
Label
Status
Error Flag
P_ER
OFF
Note:
•
Specify Step Timers in the form
step_name
.T. Refer to
2-3-1
Steps for details
.
•
Refer to
2-3-1 Steps
for information on using this instruction.
•
This instruction cannot be input or displayed on a Programming Console. “?” will be displayed.
Summary of Contents for SYSMAC CX-Programmer 8.1
Page 1: ...Operation Manual SFC Programming SYSMAC WS02 CXPC1 V8 CX Programmer Ver 8 1 Cat No W469 E1 04...
Page 2: ...ii CX Programmer Ver 8 1 WS02 CXPC1 V8 Operation Manual SFC Programming Revised February 2009...
Page 16: ......
Page 56: ...Precautions When Creating SFC Programs Section 1 5 40...
Page 118: ...Monitoring Section 4 5 102...
Page 150: ...Index 134...
Page 152: ...Revision History 136...
Page 153: ......