82
4. Input the SV for T001 (#0010 = 1.0 s).
B
1
A
0
00006 TIM DATA
#0010
WRITE
00007READ
NOP(000)
The following key operations are used to input the 2-second timer.
1, 2, 3...
1. Input the normally open condition IR 20000.
LD
C
2
A
0
A
0
A
0
A
0
00007
LD 20000
WRITE
00008READ
NOP(000)
2. Input the normally closed AND condition T002.
(It isn‘t necessary to input leading zeroes.)
AND
NOT
TIM
C
2
00008
AND NOT TIM 002
WRITE
00009READ
NOP(000)
3. Input the 2-second timer T002.
TIM
C
2
00009
TIM 002
WRITE
00009 TIM DATA
#0000
4. Input the SV for T002 (#0020 = 1.0 s).
C
2
A
0
00009 TIM DATA
#0020
WRITE
00010READ
NOP(000)
The following key operations are used to input the 10-count counter.
1, 2, 3...
1. Input the normally open condition IR 20000.
LD
C
2
A
0
A
0
A
0
A
0
00010
LD 20000
WRITE
00011READ
NOP(000)
2. Input the normally open AND condition T001.
(It isn‘t necessary to input leading zeroes.)
AND
TIM
B
1
00011
AND TIM 001
WRITE
00012READ
NOP(000)
3. Input the normally closed condition IR 20000.
LD
NOT
C
2
A
0
A
0
A
0
A
0
00012
LD NOT 20000
WRITE
00013READ
NOP(000)
(3) Inputting the
Two-second Timer
(4) Inputting the 10-count
Counter
Programming Example
Section 4-4
Summary of Contents for SYSMAC CPM1
Page 1: ...Cat No W262 E1 4 Programmable Controllers SYSMAC CPM1 OPERATION MANUAL ...
Page 2: ...CPM1 Programmable Controllers Operation Manual Revised February 1998 ...
Page 116: ...105 Appendix B Dimensions All dimensions are in millimeters CPM1 10CDR j 121 130 85 81 90 ...
Page 118: ...Appendix B Dimensions 107 CPM1 20EDR 81 90 171 180 85 ...
Page 119: ...Appendix B Dimensions 108 CPM1 CIF01 90 81 21 30 205 50 56 CPM1 CIF11 90 81 21 30 205 50 61 ...