74
3. Press the Down Arrow Key and then the CHG Key.
↓
CHG
00201DATA?
T001 #0123 #????
4. At this point a new SV constant can be input or the SV constant can be
changed to a word address designation
a) To input a new SV constant, input the constant and press the WRITE
Key.
B
1
C
2
E
4
WRITE
00201 TIM DATA
#0124
b) To change to a word address designation, input the word address and
press the WRITE Key.
SHIFT
CH
*
B
1
A
0
WRITE
00201 TIM DATA
010
This operation can be used to increment and decrement an SV constant. It is
possible only when the SV has been entered as a constant.
1, 2, 3...
1. Press the CLR Key to bring up the initial display.
2. Display the desired timer or counter.
TIM
SRCH
00201SRCH
TIM 000
3. Press the Down Arrow, CHG, and then the EXT Key.
↓
CHG
EXT
00201DATA ? U/D
T000 #0123 #0123
The constant on the left is the old SV and the constant on the right will
become the new SV constant in step 5.
4. Press the Up and Down Arrow Keys to increment and decrement the con-
stant on the right. (In this case the SV is incremented once.)
↑
00201DATA ? U/D
T000 #0123 #0124
5. Press the CLR Key twice to change the timer’s SV to the new value.
CLR
CLR
00201 TIM DATA
#0124
4-3-19 Hexadecimal, BCD Data Modification
This operation is used to change the BCD or hexadecimal value of a word
being monitored using the procedure described in 4-3-11 Bit, Digit, Word
Monitor. It is possible in MONITOR or PROGRAM mode only.
RUN
MONITOR
PROGRAM
No
OK
OK
Words SR 253 to SR 255 cannot be changed.
Caution
Check that there is no effect on equipment before changing the present values.
1, 2, 3...
1. Monitor the status of the desired word according to the procedure described
in 4-3-11 Bit, Digit, Word Monitor. If two or more words are being monitored,
the desired word should be leftmost on the display.
(Word monitor)
D0000
0119
Incrementing and
Decrementing a Constant
Programming Console Operations
Section 4-3
Summary of Contents for SYSMAC CPM1
Page 1: ...Cat No W262 E1 4 Programmable Controllers SYSMAC CPM1 OPERATION MANUAL ...
Page 2: ...CPM1 Programmable Controllers Operation Manual Revised February 1998 ...
Page 116: ...105 Appendix B Dimensions All dimensions are in millimeters CPM1 10CDR j 121 130 85 81 90 ...
Page 118: ...Appendix B Dimensions 107 CPM1 20EDR 81 90 171 180 85 ...
Page 119: ...Appendix B Dimensions 108 CPM1 CIF01 90 81 21 30 205 50 56 CPM1 CIF11 90 81 21 30 205 50 61 ...