![background image](http://html1.mh-extra.com/html/omron/sysmac-c200h/sysmac-c200h_operation-manual_742423170.webp)
157
Some example Di values and the word-to-digit conversions that they produce
are shown below.
0
1
2
3
R
Di: 0011
S
S + 1
0
1
2
3
S
S + 1
S + 2
S + 3
Di: 0030
R
S
S + 1
S + 2
S + 3
0
1
2
3
Di: 0032
R
Di: 0013
0
1
2
3
S
S + 1
R
Flags
ER:
Undefined digit designator, or S plus number of digits exceeds a data
area.
Content of a source word is zero.
Indirectly addressed DM word is non-existent. (Content of
*
DM word
is not BCD, or the DM area boundary has been exceeded.)
When 00000 is ON, the following diagram encodes IR words 010 and 011 to
the first two digits of HR 20 and then encodes LR 10 and 11 to the last two
digits of HR 20. Although the status of each source word bit is not shown, it is
Example
Data Conversion
Section 5-16
Summary of Contents for SYSMAC C200H
Page 1: ...OPERATION MANUAL C200H CPU01 E 03 E 11 E SYSMAC Programmable Controllers Cat No W130 E1 05 ...
Page 2: ...C200H Programmable Controllers CPU01 E 03 E 11 E Operation Manual Revised June 2003 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 8: ...TABLE OF CONTENTS ix Glossary 345 Index 363 Revision History 369 ...
Page 342: ...336 Programmer Program Date Page Word Contents Notes Word Contents Notes Data Storage ...
Page 374: ...Cat No W130 E1 05 C200H Programmable Controllers CPU01 E 03 E 11 E OPERATION MANUAL ...