7 Digital Output Units
7 - 16
NX-series Digital I/O Unit User’s Manual (W521)
2
Make the following settings according to the type of NX Unit you want to set.
Two-point or Four-point Output Unit (Data type: BOOL)
Select
False
(OFF) or
True
(Hold the present value) from the list of Load Rejection Output
Setting for which the output bit you want to set.
Eight-point, Sixteen-point, and Thirty-two-point Output Units
Enter a set value in the Value text box. The data type of the set values and the range of the
values that you can set vary depending on the number of output points.
Additional Information
• If you set a value different from the default value, the Value on the Sysmac Studio is dis-
played in a different color.
• You can click the
Return to Default Value
Button to return all set values on the Sysmac Stu-
dio to the default values.
• Help for the settings is displayed at the bottom of the Edit Unit Operation Settings Tab Page.
Number of output points
Data type
Set value
8 points
USINT
0 to 255
16 points
UINT
0 to 65535
32 points
UDINT
0 to 4294967295
Summary of Contents for NX-IA3117
Page 34: ...Sections in this Manual 32 NX series Digital I O Unit User s Manual W521...
Page 52: ...1 Features and System Configuration 1 18 NX series Digital I O Unit User s Manual W521...
Page 56: ...2 Specifications 2 4 NX series Digital I O Unit User s Manual W521...
Page 152: ...5 I O Refreshing 5 36 NX series Digital I O Unit User s Manual W521...
Page 204: ...8 Digital Mixed I O Units 8 8 NX series Digital I O Unit User s Manual W521...
Page 224: ...9 Troubleshooting 9 20 NX series Digital I O Unit User s Manual W521...
Page 230: ...10 Inspection and Maintenance 10 6 NX series Digital I O Unit User s Manual W521...
Page 337: ...I 1 I NX series Digital I O Unit User s Manual W521 Index...
Page 340: ...I 4 NX series Digital I O Unit User s Manual W521 Index...