1 Features and System Configuration
1 - 16
NX-series Digital I/O Unit User’s Manual (W521)
1-4-3
Digital Mixed I/O Units
Function name
Description
Reference
Free-Run Refreshing
With this I/O refreshing method, the refresh cycle of the NX
bus and the I/O refresh cycles of the NX Units are asynchro-
nous.
Synchronous I/O Refresh-
ing
With this I/O refreshing method, the timing to read inputs or to
refresh outputs is synchronous on a fixed interval between
more than one NX Unit on more than one Slave Terminal.
5-2-5 Synchro-
nous Input
Refreshing
Input Filter
This function eliminates the chattering or the noises from input
signals.
It is used to prevent the error reading due to the noises. You
can set the filter time constant.
Load Rejection Output
Setting
A function that performs the preset output operation when the
Digital Output Unit cannot receive output data due to a host
error on the Communications Coupler Unit or an error on the
NX bus.
7-4-2 Load Rejec-
tion Output Setting
Load Short-circuit Protec-
tion
A function in which the output will turn OFF to protect the out-
put circuit when an overload or load short-circuit occurs due to
a failure of the connected external devices.
Summary of Contents for NX-IA3117
Page 34: ...Sections in this Manual 32 NX series Digital I O Unit User s Manual W521...
Page 52: ...1 Features and System Configuration 1 18 NX series Digital I O Unit User s Manual W521...
Page 56: ...2 Specifications 2 4 NX series Digital I O Unit User s Manual W521...
Page 152: ...5 I O Refreshing 5 36 NX series Digital I O Unit User s Manual W521...
Page 204: ...8 Digital Mixed I O Units 8 8 NX series Digital I O Unit User s Manual W521...
Page 224: ...9 Troubleshooting 9 20 NX series Digital I O Unit User s Manual W521...
Page 230: ...10 Inspection and Maintenance 10 6 NX series Digital I O Unit User s Manual W521...
Page 337: ...I 1 I NX series Digital I O Unit User s Manual W521 Index...
Page 340: ...I 4 NX series Digital I O Unit User s Manual W521 Index...