92
Removable Box Application Examples
Appendix E
(5) Edit the macro.
PLC addresses are use for the following applications.
Note
When entering the above macro for each NSH5 project, be sure the PLC write address is not used by
any other project. Duplicate project addresses will result in the PLC not being able to correctly judge
which NSH5 PT is connected to which Removable Box.
(6) After all settings have been entered, click the
OK
Button in the Edit Macro Dialog Box, in the When a
Bit Changed Dialog Box, and in the Project Property Dialog Box to close them.
(7) Select
PT
from the System Setting Menu.
(8) Click the
Initial
Tab in the System Setting Dialog Box.
(9) Change the
$SB Allocation Address
and the
$SW Allocation Address
Fields. After entering the new
data, click the
OK
Button to close the dialog box.
Address
Application
DM00200
Stores the station number of the Removable Box that is connected to NSH5 No. 1.
DM00201
Stores the station number of the Removable Box that is connected to NSH5 No. 2.
DM00202
Stores the station number of the Removable Box that is connected to NSH5 No. 3.
WRITECMEM([SERIALA:DM00 201],$W1000,1);
SHOWPAGE($W1000);
Change the station no. write destination.
(For project No. 2 enter
DM00201
, and
for No. 3 enter
DM00202
.)
For NSH5 No. 2, enter
SERIALA:00050
and
SERIALA:DM00050
.
For NSH5 No. 3, enter
SERIALA:00100
and
SERIALA:DM00100
in each of these addresses.
Summary of Contents for NSH5
Page 2: ......
Page 4: ...iv ...
Page 12: ...xii ...
Page 16: ...xvi ...
Page 24: ...xxiv EC Directives 6 ...
Page 58: ...34 Installing the Mounting Bracket Section 2 5 ...
Page 86: ...62 Connection Method Section 4 5 ...
Page 92: ...68 Precautions When Replacing the PT Section 5 4 ...
Page 98: ...74 General Specifications Appendix A ...
Page 99: ...75 Appendix B Dimensions 75 50 176 223 75 Four M4 70 5 16 5 ...
Page 102: ...78 Types of Memory Appendix C ...
Page 107: ...83 Recommended Enabling Circuits Appendix D Program Example ...
Page 108: ...84 Recommended Enabling Circuits Appendix D ...