Removable Box Application Examples
Appendix E
(4) Click the
OK
Button to close the System Setting Dialog Box.
3.
Creating a Screen for Each Station
Create screens for stations so that the station numbers and the screen numbers match.
4.
Macro Settings
Use the following steps to change the screen and notify the PLC of the NSH5's station number based on
changes to the Station Status Monitor Address.
(1) Select
Project Properties
from CX-Designer's PT Menu.
(2) Click the
Macro
Tab in the Project Property Dialog Box.
(3) Click the
Set
Button for the
When a bit changed
Option.
(4) Perform the following in the When a Bit Changed Dialog Box.
• Select the
When a bit changed
option.
• Enter
$SB1 in the Address
Field
• Select the
Execute when ON
Option in the
Action Timing
Area.
(5) Click the
Edit Macro
Button next to the
When a bit changed
Option.
Screen number
Application
0
Initial screen (Displayed when NSH5 is started.)
1
Screen for Station 1
2
Screen for Station 2
---
---
8
Screen for Station 8
(3) Enter
$W1000
for the Station
Status Monitor Address.
Select the option.
Enter
$SB1.
Select the
Execute when ON Option
Summary of Contents for NSH5
Page 2: ......
Page 4: ...iv ...
Page 12: ...xii ...
Page 16: ...xvi ...
Page 24: ...xxiv EC Directives 6 ...
Page 58: ...34 Installing the Mounting Bracket Section 2 5 ...
Page 86: ...62 Connection Method Section 4 5 ...
Page 92: ...68 Precautions When Replacing the PT Section 5 4 ...
Page 98: ...74 General Specifications Appendix A ...
Page 99: ...75 Appendix B Dimensions 75 50 176 223 75 Four M4 70 5 16 5 ...
Page 102: ...78 Types of Memory Appendix C ...
Page 107: ...83 Recommended Enabling Circuits Appendix D Program Example ...
Page 108: ...84 Recommended Enabling Circuits Appendix D ...