![background image](http://html1.mh-extra.com/html/omron/nsh5/nsh5_operation-manual_744522117.webp)
93
Removable Box Application Examples
Appendix E
The settings entered for each NSH5 PT are as follows:
(10)Select
Communication Setting
from the PT Menu.
(11)Double-click the
Serial Port
A Icon in the Comm. Setting Dialog Box.
(12)Enter the desired setting in the
NT Link(1:N) Unit
No. Field. Click the
OK
Button to close the dialog
box.
Enter the following numbers for each NSH5 PT.
Note
If more than one NSH5 PT is connected at the same time, be sure not to set the system memory
addresses or station numbers for more than one PT. If system memory addresses are duplicated, oper-
ation problems can occur, such as all NSH5 PTs displaying the same screen.
5.
Transferring Project Data
Connect the personal computer running CX-Designer to the NSH5 and transfer the project data (station
number screen data and other items) to the NSH5.
6.
Operation Check
Perform the following steps to check if the project data settings have been correctly entered.
(1) Connect NSH5 PTs 1, 2, and 3 to Removable Boxes 1, 3, and 8, respectively, and turn ON each
Removable Box key switches. The NSH5 PTs will start. After each NSH5 PT starts, the initial display
screen (screen 0) will appear. Also, the numbers 1, 3, and 8 will be stored in the Station Status Monitor
Address, $W1000, for NSH5 PTs 1, 2, and 3, respectively.
(2) After $SB1 is turned ON in each NSH5 PT, the “When a bit changed” macro is executed. In NSH5 No.
1, the code “WRITECMEM(SERIALA:DM00200, $W1000,1);” writes 2 to DM00200, and the code
“SHOWPAGE($W1000);” changes the screen to the screen for station number 2 (screen 2). Similarly,
NSH5 No. 2 writes 3 to DM00201, which displays screen 3. Finally, NSH5 No. 3 writes 8 to DM00202,
which displays screen 8.
NSH5
System Memory Allocation
No.1
$SB Allocation Address: SERIALA:CIO00000
$SW Allocation Address: SERIALA:DM00000
No.2
$SB Allocation Address: SERIALA:CIO00050
$SW Allocation Address: SERIALA:DM00050
No.3
$SB Allocation Address: SERIALA:CIO00100
$SW Allocation Address: SERIALA:DM00100
NSH5
Station number
No.1
0
No.2
1
No.3
2
For NSH5 No. 2, enter "1".
For NSH5 No. 3, enter "2".
Summary of Contents for NSH5
Page 2: ......
Page 4: ...iv ...
Page 12: ...xii ...
Page 16: ...xvi ...
Page 24: ...xxiv EC Directives 6 ...
Page 58: ...34 Installing the Mounting Bracket Section 2 5 ...
Page 86: ...62 Connection Method Section 4 5 ...
Page 92: ...68 Precautions When Replacing the PT Section 5 4 ...
Page 98: ...74 General Specifications Appendix A ...
Page 99: ...75 Appendix B Dimensions 75 50 176 223 75 Four M4 70 5 16 5 ...
Page 102: ...78 Types of Memory Appendix C ...
Page 107: ...83 Recommended Enabling Circuits Appendix D Program Example ...
Page 108: ...84 Recommended Enabling Circuits Appendix D ...