4
Overview
Section 1-1
• The external end of the Special Cable (3 m, 10 m) has both a 9-pin D-Sub
male connector, and loose wires for the stop/emergency stop switch,
enabling switch, and function switches.
• Screen transfers are enabled by connecting a computer running CX-
Designer to the USB port (standard feature).
• Project data can be shared with panel-mounted NS-series Programmable
Terminals.
• The Smart Active Parts library for NS-series PTs can be used.
• A Memory Card can be mounted to save screen data, data logs, opera-
tion logs, error logs, and recipes.
• The PT is waterproof to a IP65 degree of protection. (See note 2.)
• The PT features a lightweight 1-kg hand-held design.
• The removable box is automatically detected when it’s connected.
The box number is set using the DIP switch on the removable box.
When the PT is connected, the box number is automatically detected
and the screens corresponding to the box number are automatically
displayed on the PT. At the same time, the PLC can be notified of the
box number.
Note
(1) PTs with lot numbers 05X0 and earlier have the following specification for
colors (because they have STN LCDs): 256 (bit maps: 4,096). Refer to
NSH5-series PT Lot Numbers
on page 73 for information on lot numbers.
(2) Conformance is evaluated under applicable test conditions, and it may
not be possible to use the PT in every environment. When used over a
long period of time, the drip-proof packing may become damaged or dirty
and lose its effectiveness.
1-1-4
Product Specifications
Note
PTs with lot numbers 05X0 and earlier have the following specifica-
tion for colors (because they have STN LCDs): 256 (bit maps:
4,096). Refer to
NSH5-series PT Lot Numbers
on page 73 for infor-
mation on lot numbers.
1-1-5
Applications
• Setting parameters and monitoring operation when starting up equipment
or switching processes
Model
Specifications
NSH5-SQR10B-V2
NSH5-SQG10B-V2
5.7-inch color TFT LCD (See note.)
• Dots: 320 x 240
• Colors: 256 (bit maps: 32,768) (See note.)
• Screen capacity
NSH5-SQ
@
10B-V2: 60 MB
• 1 USB port (for transferring screen from the CX-Designer)
Commercially available USB cable can be connected.
• Memory Card: Can be mounted.
• Serial communications: Either RS-232C or RS-422A,
depending on the Special Cable used. The serial communi-
cations mode is 1:N NT Link.
• 1 stop/emergency stop switch (
DPST-NC c NO
bit)
• 1 enabling output (
DPST-NO)
• 10 function outputs
Summary of Contents for NSH5
Page 2: ......
Page 4: ...iv ...
Page 12: ...xii ...
Page 16: ...xvi ...
Page 24: ...xxiv EC Directives 6 ...
Page 58: ...34 Installing the Mounting Bracket Section 2 5 ...
Page 86: ...62 Connection Method Section 4 5 ...
Page 92: ...68 Precautions When Replacing the PT Section 5 4 ...
Page 98: ...74 General Specifications Appendix A ...
Page 99: ...75 Appendix B Dimensions 75 50 176 223 75 Four M4 70 5 16 5 ...
Page 102: ...78 Types of Memory Appendix C ...
Page 107: ...83 Recommended Enabling Circuits Appendix D Program Example ...
Page 108: ...84 Recommended Enabling Circuits Appendix D ...