46
USB Port
Section 3-6
3-6
USB Port
The USB port can be used to transfer screens created by the CX-Designer.
For details, refer to the
NS Series Setup Manual
(Cat. No. V083-E1).
3-6-1
Connecting to the USB Port
Open the cover on top of the PT, as shown in the following diagram, and con-
nect a commercially available USB cable to the USB port. (For details on
opening the cover, refer to
3-5 Memory Cards
.)
3-7
Usable Host Connection Methods
The NSH5 has one serial port corresponding to serial port A in the NS Series,
for connecting to the PLC. Unlike with the NS Series, it is not possible to con-
nect using serial port B, the Ethernet port, or Controller Link. When using CX-
Designer to set the connection method, do not set any communications ports
other than serial port A.
The communications methods shown in the following table can be set, using
the serial port.
Note
(1) Only one NSH5 can be connected to any one communications port on the
PLC. More than one PT cannot be connected at the same time.
(2) Only PT memory can be allocated as the notification destination for the
emergency stop switch and function switches F3 to F5 and F8 to F10.
Host allocations are not possible.
The PT can also communicate with the following products:
• Mitsubishi FX-series, A-series, and Q-series PLCs
• SIEMENS S7-300-series PLCs
• Yaskawa MP-series Machine Controllers
• Yaskawa Varispeed F7-series and VS mini V7-series Inverters
• Rockwell Automation (Allen-Bradley) SLC500, MicroLogix, PLC-5, Com-
pactLogix, and ControlLogix Controllers
• Products supporting Modbus RTU
Host connection method
Usability
1:N NT Link
OK (See note 1.)
1:1 NT Link
OK
Host Link
OK
(Host Link OK with restrictions) (See note 2.)
Summary of Contents for NSH5
Page 2: ......
Page 4: ...iv ...
Page 12: ...xii ...
Page 16: ...xvi ...
Page 24: ...xxiv EC Directives 6 ...
Page 58: ...34 Installing the Mounting Bracket Section 2 5 ...
Page 86: ...62 Connection Method Section 4 5 ...
Page 92: ...68 Precautions When Replacing the PT Section 5 4 ...
Page 98: ...74 General Specifications Appendix A ...
Page 99: ...75 Appendix B Dimensions 75 50 176 223 75 Four M4 70 5 16 5 ...
Page 102: ...78 Types of Memory Appendix C ...
Page 107: ...83 Recommended Enabling Circuits Appendix D Program Example ...
Page 108: ...84 Recommended Enabling Circuits Appendix D ...