H5CX-B
@-N
34
Characteristics
Applicable Standards
I/O Functions
Response Delay Time When Resetting (Transistor Output)
The following table shows the delay from when the reset signal is input until the output is turned OFF.
(Reference value)
Accuracy of operating time
and setting error
(including temperature and
voltage influences)
Power-ON start: ±0.01% ±50 ms max. (See note 1.)
Signal start: ±0.005%±0.03 ms max. (See note 1.)
Signal start for transistor output model: ±0.005%±3 ms max. (See note 1 and 2.)
If the set value is within the sensor waiting time at startup the control output of the H5CX will not turn ON until the sensor waiting
time passes.
Note: 1.
The values are based on the set value.
2.
The value is applied for a minimum pulse width of 1 ms.
Insulation resistance
100 M
Ω
min. (at 500 VDC) between current-carrying terminal and exposed non-current-carrying metal parts
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts
1,000 VAC, 50/60 Hz for 1 min between control output, power supply, and input circuit
Impulse withstand voltage
1.0 kV (between power terminals)
1.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts)
Noise immunity
±480 V (between power terminals) and ±600 V (between input terminals), square-wave noise by noise simulator
(pulse width: 100 ns/1 µs, 1-ns rise)
Static immunity
Destruction: 15 kV
Malfunction: 8 kV
Vibration
resistance
Destruction
10 to 55 Hz with 0.75-mm single amplitude in three directions for 2 h each
Malfunction
10 to 55 Hz with 0.35-mm single amplitude in three directions for 10 min each
Shock
resistance
Destruction
300 m/s
2
in three directions, three cycles
Malfunction
100m/s
2
in three directions, three cycles
Weight
Approx. 105 g (Timer only)
Approved safety standards
UL508/Listing, CSA C22.2 No. 14, conforms to EN 61812-1 (pollution degree 2/overvoltage category III)
Conforms to VDE0106/P100 (finger protection).
EMC
(EMI)
Emission Enclosure:
(EMS)
Immunity ESD:
Immunity RF-interference:
Immunity Conducted Disturbance:
Immunity Burst:
Immunity Surge:
EN61812-1
EN55011 Group 1 class A
EN61812-1
EN61000-4-2: 6 kV contact discharge (level 2)
8 kV air discharge (level 3)
EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3);
10 V/m (Pulse-modulated, 900 MHz 5 MHz) (level 3)
EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3)
EN61000-4-4: 2 kV power-line (level 3);
1 kV I/O signal-line (level 4)
EN61000-4-5: 1 kV line to lines (power and output lines) (level 3);
2 kV line to ground (power and output lines) (level 3)
Inputs
Start signal
Starts timing.
Reset
• Resets present value. (The present value returns to 0.)
• Timing stops and control output turns OFF while reset input is ON.
• Reset indicator is lit while reset input is ON.
Gate
Inhibits timer operation.
Outputs
Forecast value
setting
Control output (OUT2)
Turns ON when the present value reaches the set value.
Forecast output (OUT1)
Turns ON when the present value reaches the forecast value.
Absolute value
setting
Control output 2 (OUT2)
Turns ON when the present value reaches set value 2.
Control output 1 (OUT1)
Turns ON when the present value reaches set value 1.
Minimum reset signal width
Output delay time
1 ms
0.8 to 1.2 ms
20 ms
15 to 25 ms