H5CX-B
@-N
36
Nomenclature
Key Protect Level
W
hen the Key-protect Switch is ON, key operations are prohibited
according to the settings for DIP switch pins 6 to 8, thus preventing
setting errors.
The Key-protect Switch can be turned ON and OFF while the power
is ON.
The Key Protection Indicator is lit orange when the Key-protect Switch
is ON.
If the key protect switch is ON, you will not be able to switch to
Function Setting Mode.
Dimensions
(unit: mm)
Digital Timers
Accessories (Order Separately)
Refer to
page 12
for details.
OFF
(Disa
b
led)
O
N
(Ena
b
led)
(Defa
u
lt setting)
11
12
10mm
6mm
1
2
3
8
9
4
6
7
5
10
Display Section
3. Reset Indicator
(orange)
1. Key Protection Indicator
(orange)
2. Control Output Indicator
(orange)
4. Present Value Display
(red)
Character height: 10 mm
7. Set Value 1, 2 Indicator
(green)
If the time range is 0.0 min or 0.0 h, the decimal
point flashes to indicate timing operation.
6. Set Value
(green)
Character height: 6 mm
5. Time Unit Indicators
(green)
Lit
w
hen the reset inp
u
t or Reset Key is O
N
.
Lit
w
hen the reset inp
u
t or Reset Key is O
N
.
Forecast
v
al
u
e setting
Operation Key
8
. Mode Key
9. Reset Key
Switches
11. Key-protect Switch
12. DIP Switch
First digit
Sixth digit
A
b
sol
u
te
v
al
u
e setting
(Changes modes and setting items)
Resets present
v
al
u
e and o
u
tp
u
t.
Character Size
for Present
V
al
u
e Display
Character Size
for Set
V
al
u
e
Display
Forecast o
u
tp
u
t O
N
: OUT 1 is lit.
Control o
u
tp
u
t O
N
: OUT 2 is lit.
Control o
u
tp
u
t 1 O
N
: OUT 1 is lit.
Control o
u
tp
u
t 2 O
N
: OUT 2 is lit.
10. Up Keys 1 to 6
OFF
O
N
1
2
3
4
5
6
7
8
Digital Timers
H5CX-BWSD-N (Flush Mounting Models)
44.
8
×44.
8
59
6
4
8
×4
8
Note:
M3.5 terminal screw (effective length: 6 mm)
Panel Cutouts
Panel cutouts areas shown below. (according
to DIN43700)
Note:
1.
The mounting panel thickness should
be 1 to 5 mm.
2.
To allow easier operation, it is
recommended that Adapters be
mounted so that the gap between
sides with hooks is at least 15 mm
(i.e., with the panel cutouts separated
by at least 60 mm).
3.
It is possible to mount Timers side by
side, but only in the direction without
the hooks. However, if Timers are
mounted side by side, water
resistance will be lost.
60 min.
60 min.
45
+0.6
–0
45
+0.6
–0
15 min.
n side by side mounting
A
A= (48n–2.5)
+1
–0
With Y92A-48F1 attached.
A={48n–2.5+(n–1)×4}
+1
–0
With Y92A-48 attached.
A= (51n–5.5)
+1
–0
Dimensions with Flush Mounting Adapter
H5CX-BWSD-N (Provided with Adapter and Waterproof Packing)
58
48
7.5
57.5
(51)
Y92F-30 (provided)
Flush Mounting Adapter
Panel
Y92S-29 (provided)