H5CX-A
@-N/-L@-N
16
Timer
R
u
n mode
Po
w
er O
N
F
u
nction setting mode
Set the time range
u
sing the keys.
Set the timer mode
u
sing the keys.
Set the o
u
tp
u
t mode
u
sing the keys.
Set the inp
u
t signal
w
idth
u
sing the keys.
Set the
N
P
N
/P
N
P mode
u
sing the keys.
Set the display color
u
sing the keys.
Set the f
u
nction (instantaneo
u
s or time-limit operation) for the instantaneo
u
s o
u
tp
u
t (o
u
tp
u
t 1)
u
sing the Keys.
Set each digit for the o
u
tp
u
t time
u
sing the corresponding keys.
For details, refer to the
Time Ran
g
e List
.
(If the o
u
tp
u
t time is set to 0.00, is displayed.)
*1.
If the mode is s
w
itched to the f
u
nction setting mode d
u
ring operation, operation
w
ill contin
u
e.
*2.
Changes made to settings in f
u
nction setting mode are ena
b
led for the first time
w
hen the mode is changed to r
u
n mode.
Also,
w
hen settings are changed, the timer is reset (time initialized and o
u
tp
u
t t
u
rned OFF).
Display
Set Value
Time Ran
g
e List
0.01 s to 99.99 s
(defa
u
lt setting)
0.1 s to 999.9 s
1 s to 9999 s
0 min 01 s to
99 min 59 s
0.1 min to
999.9 min
1 min to
9999 min
0 h 01 min to
99 h 59 min
0.1 h to 999.9 h
1 h to 9999 h
0.001 s to
9.999 s
~
Time range
Timer mode
O
u
tp
u
t modes
O
u
tp
u
t time
Inp
u
t signal
N
P
N
/P
N
P
inp
u
t
Display color
Instantaneo
u
s/
time-limit
To next page
From next page
s
s
h
s
(DOW
N
)
(UP)
(1ms)
(20ms)
(A-1)
(A-2)
(A-3)
(
b
-1)
(
b
)
(d)
(E)
(F)
(S)
(Z)
(A)
(0.01s)
(99.99s)
(O
u
tp
u
t hold)
Note:
Displayed for modes A, A-1, A-2, A-3,
b
,
b
-1 and S only.
Note:
Only modes
A-2
,
b
, E, and Z can
b
e selected for models
w
ith instantaneo
u
s
contact
o
u
tp
u
ts.
(P
N
P inp
u
t)
(
N
P
N
inp
u
t)
Note:
Only displayed for the H5CX-A
@
and H5CX-A11
@
.
(Red)
(Green)
(Orange)
(Red-green)
(Green-red)
(Red-orange)
(Orange-red) (Green-orange)(Orange-green)
Note:
Displayed only for models
w
ith terminal scre
w
s (H5CX-A
@
).
Note:
Displayed only for models
w
ith instantaneo
u
s contact o
u
tp
u
ts.
3 s min.
*
2
3 s min.
*
1
The characters displayed in re
v
erse
v
ideo are the defa
u
lt settings.
When performing settings
w
ith operation keys only, set pin1 of the DIP s
w
itch to OFF (factory setting).
If pin 1 of the DIP s
w
itch is set to O
N
, the setting items indicated in
w
ill not
b
e displayed.
(Instantaneo
u
s) (Time-limit)
Step2
Settings that cannot
b
e performed
w
ith the DIP s
w
itch are performed
w
ith the operation keys.
• Change to F
u
nction Setting Mode.
Note:
N
ot displayed for models
w
ith instantaneo
u
s contact o
u
tp
u
ts.
F
u
nction setting mode
……
s
20ms
1ms
pnp
grn
2c
1c1c
red
org
r-g
g-r
r-o
o-r
g-o
o-g
npn
down
up
z
a-1
a
a-2
99.99
0.01
hold
hold
a-3
b
b-1
d
e
f
s
For details on operations in run mode, refer to
page 19
.