
H5CX-B
@-N
37
Operating Procedures
DIP Switch Settings
All functions are set using the DIP switch.
Operation in Run Mode
Forecast Value Setting
Absolute Value Setting
Note: 1.
All the pins are factory-set to OFF.
2.
DIP switch settings are effective when the power is
turned ON again. (Set the DIP switch before installation
and power-up.)
Item
OFF
ON
1
Time range
Refer to the table on the
right.
2
3
Output modes
F-1 mode
A mode
4
Input signal width
20 ms
1 ms
5
NPN/PNP input mode
NPN
(no-voltage)
PNP
(voltage)
6
Reset Key protection
Disabled
Enabled
7
Up Key protection
Disabled
Enabled
8
Mode Key protection
Disabled
Enabled
Pin 1
Pin 2
Time range
OFF
OFF
0.1 h to 99999.9 h
ON
OFF
0.01 s to 9999.99 s
OFF
ON
0 h 00 min 01 s to
99 h 59 min 59 s
ON
ON
0.1 min to 99999.9 min
OFF
O
N
1
2
3
4
5
6
7
8
Set the digits for the set values using the corresponding
Key.
Set value
Present value
Forecast set value
Present value
Each time the Key is pressed,
the sub-display will switch between
the set value (“SET” is lit) and the
forecast set value (“1” is lit).
Set value 1
Present value
Set value 2
Present value
Each time the Key is pressed,
the sub-display will switch between
set value 1 (“SET 1” is lit) and set
value 2 (“SET 2” is lit).