H5CX-B
@-N
33
• H5CX Digital Timers with 6-digit Display, 2-stage Setting,
and Forecast Output (DIN 48 x 48-mm)
• Times the daily operating hours of machinery and tools,
predicting and notifying when maintenance is required.
• Easy-to-read backlit negative LCD with 6 digits (displays
to 99999.9 h).
• The 2-stage settings and forecast output are ideal for
maintenance applications.
Specifications
Ratings
*1.
Inrush current will flow for a short time when the power supply is turned ON.
Inrush Current (Reference Values)
*2.
The display is lit only when the power is ON.
Digital Timer H5CX-B
@
-N
Classification
Digital Timer with 6-digit display, 2-stage setting, and forecast output
Ratings
Power supply voltage
12 to 24 VDC
Operating voltage
fluctuation range
90% to 110% rated supply voltage
Power consumption
Approx. 2.3
W
*1
Mounting method
Flush mounting
External connections
Screw terminals
Degree of protection
IEC IP66, UL508 Type 4X (indoors) for panel front surface only and only when Y92S-29
W
aterproof Packing is used
Digits
6 digits
Time range
0.01 s to 9999.99 s, 1 s to 99 h 59 min 59 s, 0.1 min to 99999.9 min, 0.1 h to 99999.9 h
Timer mode
Elapsed time (Up)
Inputs
Input signals
Signal, reset, gate
Input method
No-voltage Input
ON impedance
: 1 k
Ω
max. (Leakage current: 12 mA when 0
Ω
)
ON residual voltage : 3 V max.
OFF impedance
: 100 k
Ω
min.
Voltage Input
High (logic) level
: 4.5 to 30 VDC
Low (logic) level
: 0 to 2 VDC (Input resistance: approx. 4.7 k
Ω
)
No-voltage (NPN) input/voltage (PNP) input (switchable)
Signal, reset, gate
Minimum input signal width: 1 or 20 ms (selectable, same for all input)
Reset system
Power resets (only for A mode), external and manual reset
Power reset
Minimum power-opening time: 0.5 s (except for F-1 mode)
Reset voltage
10% max. of rated supply voltage
Sensor waiting time
250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
Outputs
Output modes
A, F-1
Output type
Transistor output: NPN open collector, 100 mA at 30 VDC max. residual voltage: 1.5 VDC max. (Approx. 1 V)
Leakage current: 0.1 mA max.
Display
7-segment, negative transmissive LCD;
Present value: 10-mm-high characters, red
Set value: 6-mm-high characters, green
*2
Memory backup
EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Operating temperature range
-10 to 55°C (-10 to 50°C if counters are mounted side by side) (with no icing or condensation)
Storage temperature range
-25 to 70°C (with no icing or condensation)
Operating humidity range
25 to 85%
Case color
Black (N1.5)
Attachments
W
aterproof packing, flush mounting adapter, unit label
Voltage
Applied voltage
Inrush current (peak value)
Time
12 to 24 VDC
26.4 VDC
4.4 A
1.7 ms