manualshive.com logo in svg
background image

 

 

 

 

 

 

 

Version-E20-03-31 

Manual 

Mobile Timing 

MT1 

Содержание Mobile Timing MT1

Страница 1: ...Version E20 03 31 Manual Mobile Timing MT1 ...

Страница 2: ...ic supply that has been installed by an electrician according to IEC 60364 1 Never touch the mains plug with wet hands Never touch live parts Cleaning Detergents can cause damage Never submerge in water or open The cleaning must not be carried out by hose or high pressure risk of short circuits or other damage Liability Limitations All technical information data and information for installation an...

Страница 3: ...ds normative documents and in case of intended use com plies with the basic requirements of R TTE 1999 5 EC Telecommunication TC terminal device Short Range Device Applied harmonized standards EN 60950 1 2006 A11 2009 A1 2010 A12 2011 A2 2013 EMC EN301 489 17 v2 1 1 2009 05 v2 2 1 2012 09 EN 300 328 v1 7 1 2006 10 v1 9 1 2015 02 EN 55022 2010 AC 2011 EN 55024 2010 A1 2015 EN 61000 3 2 2014 EN 6100...

Страница 4: ...ime 6 2 2 Keypad 6 2 3 Connections 6 2 3 1 Timing channels 6 2 3 2 USB 6 3 Operation 8 3 1 Menu 8 3 1 1 Channel blocking 8 3 1 2 Memo 9 3 1 3 Scroll 9 3 1 4 General 9 4 GPS 11 5 Software 12 5 1 alge results com platform 12 5 2 Create account 12 5 3 Add device 12 5 3 1 Evaluation software 13 5 3 2 Time NET Connector 13 6 Technical data 14 ...

Страница 5: ...ce will show its name ID Power off Press the OFF button for 3 seconds The MT1 will ask for confirmation Release the OFF but ton and press it again to confirm You can abort this with the ESC or any other button 2 1 Display The OLED display of the MT1 has a resolution of 128x64 The display is switched off after 5 minutes idling The display is reactivated by any button or timing impulse 2 1 1 Status ...

Страница 6: ...2 1 3 Time On the lower end of the screen there is on the main screen the running time On the very lower end of the screen you can see the last timing impulse channel bib and time 2 2 Keypad The MT1 has a splash proof foil keyboard with 12 buttons 2 3 Connections 2 3 1 Timing channels There are two timing channels on banana plugs One green C0 and black and one red C1 and black 2 3 2 USB The MT1 de...

Страница 7: ...install this software and then connect the MT1 to the PC Otherwise it can be necessary to re attach the MT1 device You can choose if you want to update the latest firmware version from internet or from local file which can be useful for offline installation As soon as the MT1 is found in the firmware update software you can press start update to start the update process After the download is finis...

Страница 8: ...e Disabled and Blocked If a timing channel is Disabled no time is stored That is used on breaks to avoid unnecessary data transmission Use Blocked during the event when you are not sure if the next impulse is valid or not Use Active at normal operation You can navigate with the arrow buttons To react very fast this setting is immediately active You do not have to confirm You can return to main men...

Страница 9: ... to the desired time Press Enter to edit Then you can enter the bib and confirm it with ENTER Exit the memo mode with the ESC button 3 1 3 Scroll At the scroll menu you can check the timing impulses and manipulate the bib information Scroll with the arrow buttons 2 for scroll up 8 for scroll down to the time you want to change With the ENTER button you can edit the bib number Enter the new bib and...

Страница 10: ...timing impulses will be overwritten Here you can delete stored times You have to confirm with ENTER if you want to proceed Otherwise press ESC to exit 3 1 4 3 Sync out You can synchronize other devices with a timing impulse on C0 A confirmation will be dis played at full minute Note This function is only available if the MT1 device itself is in synchronized state 3 1 4 4 Mobile Network Mobile stat...

Страница 11: ...e is a mail function on the mobile network it can be necessary to execute a manual reconnect to re establish mobile connection 3 1 4 5 GPS If there is no GPS available At the next picture you can see a normal operation with more than 3 satellites in view In this example there are 7 satellites in use and 26 satellites in view You also can see the altitude and GPS signal strength of the 7 best satel...

Страница 12: ...es must not be closer than 30 cm to each other This can disturb GPS reception 5 Software 5 1 alge results com platform The MT1 system is maintained over the www alge results com website Open your webbrows er and navigate to www alge results com Then login If you do not have an account you have to create one Note IE11 and older browsers are not supported 5 2 Create account Then please fill up the s...

Страница 13: ...rigger you can see the received impulses Second action is re read That action will read the current status of the MT1 device Third action will remove the device from your account Note If you want to pass your device to another timer you have to remove it from your account first A device can only belong to one account at a time To get some more information about the alge results com platform we pro...

Страница 14: ...which simulates and connects two COM ports This COM port simulator Com0Com can be downloaded on our website If you use the Time NET software we suggest to use the network connection to the Time NET connector which will be automatically established An IDCam device will be simulated in this case Note Timing impulses of non MT1 devices are not reflected to the online platform alge results com ...

Страница 15: ...ors Operating temperature 20 to 65 C Time base Self calibrating TCXO quartz Synchronization External via internal GPS or UMTS Operating time 12h at 25 C with one impulse per minute Charging time app 2h at 25 C Time memory 7000 times Battery li Ion rechargeable battery 3 6 V 10 4 Wh integrated Measurements 22 x 74 x 34 mm Weight 235g 0 5 lb ...

Страница 16: ...Manual Mobile Timing MT1 16 Subject to changes Copyright by ALGE TIMING GmbH Rotkreuzstr 39 6890 Lustenau Austria www alge timing com ...

Отзывы: