H5CX-A
@-N/-L@-N
21
Timer
Mode b: Repeat cycle 1 (Timer resets when power comes ON.)
Basic operation
Detailed operation
*
Start signal input is disabled during timing.
Timing starts when the start signal goes ON.
The status of the control output is reversed when time
is up (OFF at start).
W
hile the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note:
Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms (contact
output type).
Sustained Output
*
Start signal input is disabled during timing.
Timing starts when the start signal goes ON.
The control output is turned ON when time is up.
W
hile the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note:
Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms (contact
output type).
One-shot Output
Mode b-1: Repeat cycle 2 (Timer does not reset when power comes ON.)
Basic operation
Detailed operation
*
Start signal input is disabled during timing.
Timing starts when the start signal goes ON.
The status of the control output is reversed when time
is up (OFF at start).
W
hile the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note:
Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms (contact
output type).
Sustained Output
*
Start signal input is disabled during timing.
Timing starts when the start signal goes ON.
The control output is turned ON when time is up.
W
hile the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note:
Normal output operation will not be possible if
the set time is too short.
Set the value to at least 100 ms (contact
output type).
One-shot Output
Po
w
er
O
u
tp
u
t
*
Start signal
inp
u
t
Timing
Timing
Timing
Timing
0
0
Power
Start signal
Gate
Reset
Control output
Set value
Set value
UP
DOWN
Timing diag
ram
Po
w
er
O
u
tp
u
t
*
Start signal
inp
u
t
Timing
Timing
Timing
Timing
t
t
0
0
Po
w
er
Start signal
Gate
Reset
Control o
u
tp
u
t
Set
v
al
u
e
Set
v
al
u
e
UP
DOW
N
Timing diag
ram
Po
w
er
O
u
tp
u
t
*
Start signal
inp
u
t
Timing
Timing
Timing
Timing
S
u
stained
Timing
0
0
Power
Start signal
Gate
Reset
Control output
Set value
Set value
UP
DOWN
Timing diag
ram
Po
w
er
O
u
tp
u
t
*
Start signal
inp
u
t
Timing
Timing
Timing
Timing
S
u
stained
Timing
t
t
t
t
t
0
0
Po
w
er
Start signal
Gate
Reset
Control o
u
tp
u
t
Set
v
al
u
e
Set
v
al
u
e
UP
DOW
N
Timing diag
ram