Infresco-T 6kW 
The  Infresco-T  6kW  is  part  of  a  family  of  controllers designed to provide energy saving 
when  used with Quartz Infrared Halogen Lamps or other Heating and Lighting Products. 
The ‘T’ model switches the lamps on for a pre-determined time period of between 1 and 
30  minutes.  Designed  with  ease  of  wiring  in  mind,  this  unit  is  ideal  for  controlling up to 
four 1.5kW lamps through the use of two additional cable entry points. 
The  microcontroller-based  unit  incorporates  zero-voltage  switching  and  a  soft-start 
function to eliminate the lamps’ initial high inrush current – potentially increasing lamp life 
by as much as 30% and reducing the stress on the mains supply.  

Typical use is for Infra Red 

Heating lamps, Garden lighting

 

Installation is simple and once installed is relatively maintenance free. 
 
Product Features and Benefits 
Significant energy saving – lamps are on for a pre-determined time 
Extends lamp Life 
Ideal for controlling up to 4 x 1.5kW lamps 
Soft-start/zero-voltage switch-off 
Low-cost 
Easy to install 
 
Installation 
The  Infresco-T  6kW  unit  should  be  positioned  with  the  cable  glands  facing  down  and 
securely  fixed  via  the  four  mounting holes accessible from the front of the unit or by the 
alternative  rear  mounting  holes  underneath  the  PCB.  For  the  latter  option,  remove  the 
four screws securing the PCB and carefully remove the PCB to allow access to the rear 
mounting holes. Cover any holes used with caps supplied with the unit. 
 
Wiring 
Warning! Ensure the mains supply has been isolated before wiring this unit. 
 
The  unit  is  fitted  with  three  cable  glands.  Only  one  cable  should  be  fitted  per  gland  to 
maintain  the  unit’s  IP  rating.  Two  additional  cable  glands  can  be  fitted  to  allow  the 
connection of up to four lamps. See Figure 2. 
The mains supply connects to the terminal block marked ‘LINE’. Connect the supply LIVE 
to the ‘L’ terminal, NEUTRAL to the ‘N’ terminal and EARTH to the ‘E’ terminal. 
The lamps connect to the terminal block marked ‘LOAD’. Connect the load LIVE to the ‘L’ 
terminal,  NEUTRAL  to  the  ‘N’  terminal  and  EARTH  to  the  ‘E’  terminal.    The  load 
connections are paired to allow the connection of several lamps. 
Important:  Ensure  all  earth  wires  are  connected  to  maintain  earth  continuity  to 
the lamp fittings. 

 
Check all wiring - particularly the line and load connections and make sure the cable glands 

   
 
 
 

 