![background image](http://html.mh-extra.com/html/omron/h5cx-a-n/h5cx-a-n_datasheet_744489025.webp)
H5CX-A
@-N/-L@-N
25
Twin Timer
Setting Procedure Guide
Operating Procedures for Twin Timer Function
After making DIP switch settings for basic operation, advanced functions can be added using the operation keys on the front panel. Refer to
on
page 26
for details.
Hold do
w
n for 1 s min.
Hold do
w
n for 1 s min.
Timer
Press the or Key to
s
w
itch to a T
w
in Timer.
T
w
in timer
Key-protect S
w
itch
R
u
n mode
Po
w
er O
N
Timer/t
w
in timer
selection mode
1
+
1
+
tim
1
2
3
4
5
6
7
8
OFF
O
N
Step2
Settings for
b
asic f
u
nctions can
b
e performed
w
ith j
u
st the DIP s
w
itch.
Note:
There is no DIP s
w
itch on the H5CX-L
8
@
. Go to .
Step1
S
w
itching to a T
w
in Timer
Disa
b
led
Ena
b
led
OFF
O
N
OFF
O
N
OFF
OFF
O
N
O
N
Refer to the ta
b
le on the right.
Refer to the ta
b
le on the right.
DIP s
w
itch settings
OFF time range
O
N
time range
O
u
tp
u
t mode
Timer mode
Inp
u
t signal
w
idth
UP
DOW
N
Flicker OFF start
Flicker O
N
start
20 ms
1 ms
0.01 s to 99.99 s
0.1 s to 999.9 s
1 s to 9999 s
0 min 01 s to 99 min 59 s
OFF
O
N
OFF
O
N
OFF
OFF
O
N
O
N
0.01 s to 99.99 s
0.1 s to 999.9 s
1 s to 9999 s
0 min 01 s to 99 min 59 s
Note:
All the pins are factory-set to OFF.
Step3
Be s
u
re to t
u
rn O
N
pin 1 on the DIP s
w
itch.
Changes to DIP s
w
itch settings are ena
b
led
w
hen the po
w
er is t
u
rned O
N
.
(Perform DIP s
w
itch settings
w
hile the po
w
er is OFF.)
Item
OFF
ON
OFF time ran
g
e
Pin 3
Pin 2
ON time ran
g
e
Pin 5
Pin 4
1
2
3
4
5
6
7
8
Be sure to set pin 1 to ON when usin
g
the DIP switch.
twn
Step3