background image

DIGITAL TIME SWITCH

DATA MICRO + / DATA MICRO 2+

OPERATING INSTRUCTIONS

DESCRIPTION

DATA MICRO

+

is a time switch designed to control any electrical installation.

Includes pulse programming from 1 to 59 seconds and up to 32 block memory
spaces. Automatic winter ! summer official time adjustment.

INSTALLATION

ATTENTION: Electrical devices must be installed and assembled by authorized
installer.
VERY IMPORTANT: This time switch is protected internally against interference by a
safety device. However, particularly strong electromagnetic fields may alter its
operation. Such interference can be avoided by adhering to the following
recommendations during installation:

-

The device should not be installed near inductive loads (motors, transformers,
contactors, etc)

-

A separate power line is recommended (equipped with a network filter if
necessary)

-

Inductive loads should be equipped with interference suppressors (varistor, RC
filter)

If the time switch is to be used in combination with other devices in an installation, it
is necessary to verify that no parasitic disturbances will be caused by the group.

MOUNTING: Electronic control device for independent installation in distribution
cabinet fitted with symmetrical 35 mm profile in accordance with the standard EN
60715 (DIN Rail EN 60715 (Rail DIN).

CONNECTION:

Connect according with the following schema:

STARTING UP AND PROGRAMMING

DATA MICRO

+

is already programmed with current date and time, and with the

official automatic winter ! summer official time adjustment activated (last Sunday in
March and last Sunday in October).
Programming is based in menus (indicated by icons):

x

- Programming.

x

- Clock setting.

x

- Winter / summer official time change.

x

- Holidays period programming.

RESET

Although the clock of the device is already programmed, if a RESET is needed
(blank display, inconsistent data, etc), press at the same time the four keys during 3
seconds. In this moment, the device loses all data and goes to clock setting mode,
directly to program year, month, day, day of the week, hour and minutes.

CLOCK SETTING. FIG 1.

For clock setting, press key

to access to the Menu and with keys

and

select icon

and press

. Display shows the year with the last two figures

blinking; update the year by pressing keys

and

and validate it with key

.

The same operation should be made to update month, day, day of the week, hour
and minutes. By accepting minutes with

, it automatically goes to normal mode.

To change the time mode (24h/12h am-pm) proceed as follows: accept year, month,
day and day of the week; while hour is blinking, press

and

at the same

time. After that, the time mode has change.

PROGRAMMING. FIG 2 and 3.

To program the device, press

to enter to the menu. By pressing again

the

menu

is entered and the display shows the first programmed switching. If no

switching is programmed then - - : - - is shown. To program or edit the desired
switching press

again, with keys

and

select the circuit and type of

switching: C1 OFF, C1 ON, C1 ON

, (C2 OFF, C2 ON, C2 ON

only in model

DATA MICRO 2+). Validate with

and introduce hour and minutes desired,

validating then with

. Then select the days of the week that the switching has to

operate. With keys

and

place the blinking cursor on the first day of the

week that the switching has to operate and then fix it by pressing

. Repeat this

sequence with the other days of the week when the switching has to operate. For the
days not desired, press

to go down to the next day. After programming all the

days of the week, the display will show the next switching to program.

SHORT TIME SWITCHING (PULSE) PROGRAMMING. FIG 4.

If the selected switching is a Pulse

, after introducing hour and minutes when the

pulse starts, use keys

and

to program the length of the pulse (from 1 to

59 seconds). This length is shown in the digits of seconds (situated at the right side
and smaller than the digits of hours and minutes). Select the day(s) of the week
when the switching has to be programmed and validate with

. After that, press

to come back to normal mode. If

is not pressed, being in any mode, after

two minutes, the device returns to normal mode.

VIEWING PROGRAMMED SWITCHING. FIG 5.

The programmed switching can be checked by entering again in menu

and

pressing key

all the switching are shown in display, and after the last one, the

display shows - - : - -, if there is any free space and then it shows the number of free
spaces.

EDITING OR DELETING SWITCHING

Programmed switching can be edited or deleted in menu

, selecting with keys

or

the switching to be edited or deleted. To edit it, proceed as in clause

PROGRAMMING

and to delete it, keep pressing key

and then press key

.

To delete all the switching without using RESET, go to the point where the display
shows the free spaces of memory, keep pressing key

and then press key

. The display will show 32, the total free memory spaces.

MANUAL OVERRIDE. FIG 6.

In normal mode, pressing key

(

), circuit C1 is activated or deactivated.

The same for circuit C2 by using key

(

) (only in DATA MICRO 2+).

If any manual override is executed, it is represented in display by symbol

.

The next programmed switching cancels the manual override and the symbol
disappear from the display.

PERMANENT OVERRIDE. FIG 7.

This option blocks all the programmed switching. In normal mode, keep pressing key

and then press key

(

) to activate the permanent position of circuit;

this situation is indicated in display with symbol

. After that, the state of the circuit

can be changed by pressing key

(

).

To cancel permanent override keep pressing key

and then press key

(

), symbol

disappear from display. The same for circuit C2 using key

(

) only in DATA MICRO 2+.

WINTER / SUMMER OFFICIAL TIME CHANGE. FIG 8.

Enter MENU by pressing key

; select option

using keys

and

,

validate with

. There are the three following working modes:

ƒ

AUTO: The clock is automatically changed on the last Sunday in March al 02:00
and the last Sunday in October at 03:00.

ƒ

PRO: Allows to choose the date and time for the time change, programming first
the winter ! summer change (

) and then the summer ! winter change ( ).

ƒ

OFF: No time change will be made

HOLIDAY PROGRAM. FIG 9.

This function allows deactivating the circuits during a period of time up to 99 days.
After that, the programming continues as usual.
If user validates 0 days, the holiday period is cancelled and the device will work in a
normal way. If user validates a number of days different than 0, the device starts
immediately, so relays switch to OFF and programmed switching will not execute.
If the validated number of days is 1, the holiday period will finish at 23:59:59 of the
same day than validation. If the validation number of days is 2, the holiday period will
finish next day. And so on.
Display shows symbol

during the holiday period.

Permanent overrride

Override

Holidays program

Summer / Winter time

Clock setting

On / Off

Day of the week

(1) Monday

AM / PM mode

Hour : Minute

On / Off

Programming

Circuit 1

Pulse

Circuit 2

(only Data Micro 2 +)

1

2

3

N

L

DATA MICRO +

1

2

3

N

L

4

5

6

DATA MICRO 2 +

C2

C

Confirms the selection
Starts menu

C1

OK

MENU

Display

Increment or move up

in menu

Circuit C2 override

(only Data Micro 2 +)

Decrement or move
down in menu
Circuit C1 override

Move back in menu

Permanent override

(C+C1 ó C+C2)