background image

Connect the Ground wire (Green/Bare Copper) from the wall box 

(or earth screw) to the GREEN wire of the timer using a wire nut.

Connect the Neutral wires (White) from the wall box to the WHITE

wire of the timer using a wire nut.

Connect the Hot wire (Black) from the wall box (from breaker) to the

BLACK wire of the timer.

Traveler 1: Connect Traveler 1 (from the timer) and load’s hot wire to

the COMMON terminal (usually black or copper colored) of the 3-way

switch.

Traveler 2: Connect Traveler 2 (fromt the timer) and loads’s hot wire to

the COMMON terminal (usually black or copper colored) of the 3-way

switch.

Travelers:

Traveler 1: Connect Traveler 1 (from load side) to the RED wire of the

 

       timer.

Traveler 2: Connect Traveler 2 (from load side) to the BLUE wire of the

 

       timer.

Turn DST on or off with one simple push.

The manual override button allows you to turn the timer on and off at 

any time.

Easy-to read large LCD screen with display clock.

Up to 18 ON events and 18 OFF events daily.

Random security setting allows to respectively postpone ON and OFF

times by 0-30 minutes to create a “lived-in” look.

18 ON/OFF per day

With ON/OFF/Timing shift function

With Ni-MH recharging battery

Min. Setting time: 1 minute

Max. Setting time: 7 days

Supply voltage: 125V, 60Hz

Contact rating: 15A/1875W Resistive

10A/1250W Tungsten, 10A/1250W Ballest, 1/2HP, TV-5

Operating temperature: 5°F - 122°F

Storage tempuerature: -4°F - 140°F

Insulation class: II

Protection class: IP20

Important: inductive (starting load) should always be calculated especially

when controlling lighting (because of variable inductive loads).

If this load exceeds 8 Amps then it is imperative that an electrician be used.

Connect the Ground wire (Green/Bare Copper) from the wall box 

(or earth screw) to the GREEN wire of the timer using a wire nut.

Connect the Neutral wires (WHITE) from the wall box (from breaker)

to the WHITE wire of the timer. The load’s neutral should also be

connected using a wire nut.

Connect the Lights Hot wire (Black) from the wall box to the RED

wire of the  timer. 

MEW-DT1875

When replacing an existing switch, please make sure that the

neutral wire is available in the box.

Before wiring, please cut OFF the power at the breaker.

HOT wire: Connect the Hot wire from the wall box (from breaker) to

 

      Traveler 1 (from the timer) and the jumper, then connect

 

      jumper to COMMON terminal (usually black or copper colored)

 

      of the 3-way switch.

Traveler 2: Connect Traveler 2 (from the timer) to either terminal (usually

 

       brass colored) of the 3-way switch. 

STEP 5: TURN THE POWER ON.

STEP 4: INSTALL THE TIMER AND THEN MOUNT THE WALL PLATE

MEW-DT1875

 

User Instru

ns

 

 

Connect the Ground wire (typically Green/Bare Copper) from the wall box 

(or earth screw) to the GREEN wire of the timer using a wire nut.

Connect the Neutral wires (WHITE) from the wall box to the WHITE 

wire of the

                 timer using a wire nut.

Connect the Hot wire (BLACK) from the wall box (from the breaker) to the 

BLACK wire of the timer using a wire nut. 

Connect the Load wire (Black or red) from the wall box (from the light) to the 

RED wire of the timer using a wire nut.

Use a wire nut to cap off the blue wire.

When replacing an existing switch, please make sure that the neutral wire is

available in the box.

Before wiring, please cut OFF the power at the breaker.

When replacing an existing switch, please make sure that the neutral wire is

available in the box.

Before wiring, please cut OFF the power at the breaker.

MEW-DT1875

Reviews: