Name
Model
Minimum bending
radius
Connector length
Camera Cable
FZ-VS3
69 [mm]
30 [mm]
Right-angle Camera Cable
FZ-VSL3
Bend resistant Camera Cable
FZ-VSB3
Bend resistant Right-angle Camera Cable
FZ-VSLB3
Long-distance Camera Cable
FZ-VS4
78 [mm]
42 [mm]
Long-distance Right-angle Camera Cable
FZ-VSL4
Installation in a Control Panel
• Make sure to tighten all screws in mounting.
• For good ventilation, provide a clearance of 50 [mm] or more above the Sensor Controller away
from other devices in the normal floor mounting. For the right and left sides, provide a clearance of
30 [mm] or more, and for the back side, 15 [mm] or more. These clearances are also required when
mounting multiple Sensor Controllers side by side. For the back mounting, the back-side clearance
of 15 [mm] is not required.
l
Side Mounting
19.5
143
24
141
4-M4 depth 4.5 (mounting screw hole)
19.2
143
182.5
24
141
190
20.1
4-M4 depth 4.5 (mounting screw hole)
(Unit: mm)
• Left side
• Right side
* Recommended tightening torque: 1.2 N•m to 1.3 N•m
* The tolerance is ±0.2 mm.
5 Setup and Wiring
5-32
FH Series Vision System Hardware Setup Manual (Z366-E1)
Summary of Contents for FH-2 Series
Page 8: ...Manual Structure 6 FH Series Vision System Hardware Setup Manual Z366 E1...
Page 34: ...Revision History 32 FH Series Vision System Hardware Setup Manual Z366 E1...
Page 48: ...1 Confirm the Package 1 14 FH Series Vision System Hardware Setup Manual Z366 E1...
Page 58: ...2 Overview of FH series 2 10 FH Series Vision System Hardware Setup Manual Z366 E1...
Page 148: ...3 Configuration 3 90 FH Series Vision System Hardware Setup Manual Z366 E1...
Page 235: ...I Index I 1 FH Series Vision System Hardware Setup Manual Z366 E1 I...
Page 242: ...Index I 8 FH Series Vision System Hardware Setup Manual Z366 E1...
Page 243: ......