2-4 Connecting the Communications Connector
Crimping Tool for Ferrules
Manufacturer Model
Phoenix Contact
CRIMPFOX UD6
IMPORTANT
•
Use ferrules when wiring cables.
•
I/O connectors are detachable. Tighten the screws on the I/O connector to 0.25 to
0.3 N
⋅
m.
•
The I/O connector has a structure that helps prevent incorrect wiring. Make
connections at the specified locations corresponding to the terminal numbers.
•
Do not remove the label from the DST1 before wiring.
•
Always remove the label after completing wiring to ensure proper heat dispersion.
2-4
Connecting the Communications Connector
Colored stickers are provided on the communications connector that match the colors
of the lines to be inserted. Check that the colors of the lines and stickers match when
wiring the connectors. The colors are as follows:
Color
Signal
Red
Power cable positive side (V+)
White
High side of communications data (CAN_H)
-
Shield
Blue
Low side of communications data (CAN_L)
Black
Power cable negative side (V-)
Refer to the
DeviceNet Operation Manual
(Cat.No.W267) for details on communications
specifications and wiring.
IMPORTANT
•
When connecting the communications connector to the DST1, tighten the
screws on the communications connector to 0.25 to 0.3 N
⋅
m.
•
OMRON’s S8
Power Supplies are recommended for communications
power.
Note
•
The internal power for the DST1-series Safety I/O Terminals is supplied from
the communications power supply (V+, V-).
2-5
Summary of Contents for DST1 Series
Page 2: ......
Page 3: ......
Page 4: ......
Page 5: ...DST1 series Safety I O Terminals Operation Manual Produced April 2005 ...
Page 6: ......
Page 24: ...Section 1 Overview ...
Page 44: ...Section 2 General Procedure ...
Page 50: ...Section 3 Configuration ...
Page 63: ...Section 4 Specifications ...
Page 67: ...Section 5 DST1 series ...
Page 79: ...Section 6 Troubleshooting and Maintenance ...
Page 87: ...Section 7 Wiring Examples ...
Page 97: ...Appendices ...
Page 114: ...Cat No Z904 E1 01 OPERATION MANUAL DST1 series Safety I O Terminals ...