Precautions
-
Disconnect the DST1 from power supply when wiring. Devices connected to
DST1 may operate unexpectedly.
-
Apply properly specified voltages to the DST1 inputs. Applying inappropriate DC
voltage and any AC voltages cause the DST1 to fail.
-
Be sure to separate the communication cable and the I/O cable from the
high-voltage/ current lines.
-
Be cautious not to have your fingers caught when attaching connectors to the
plugs on the DST1.
-
Mount screw of DeviceNet Connector and I/O Connector correctly.(0.25-0.3N•m)
-
Incorrect wiring may lead to loss of safety function. Wire conductors correctly
and verify the operation of the DST1 before commissioning the system in which
DST1 is incorporated.
-
After wiring is completed, be sure to remove label for wire clipping prevention on
the DST1 to enable heat to escape for proper cooling
Power Supply Selection
Use DC power supply satisfying requirements below.
-
Secondary circuits of DC power supply is isolated from its primary circuit by
double insulations or reinforced insulations
-
DC power supply satisfies the requirement for class 2 circuits or limited
voltage/current circuit stated in UL 508.
-
20ms or over of the output hold time.
Periodical Inspection and Maintenance
-
Disconnect the DST1 from power supply when replacing. Devices connected to
the DST1 may operate unexpectedly.
-
Do not dismantle, repair, or modify the DST1. It may lead to loss of its safety
functions.
Disposal
-
Be cautious not to have you injured when dismantling the DST1.
5
Additional Precautions According to UL1604
DST1-ID12SL-1 and DST1-MD16SL-1 are suitable for use in Class I, Div. 2, Group A, B,
C, D or Non-Hazardous Location Only.
WARNING – Explosion Hazard – Substitution of Components May Impair Suitability For
Class I, Div. 2.
WARNING – Explosion Hazard – Do not Disconnect Equipment Unless Power Has
Been Switched Off Or The Area Is Known To Be Non-Hazardous.
11
Summary of Contents for DST1 Series
Page 2: ......
Page 3: ......
Page 4: ......
Page 5: ...DST1 series Safety I O Terminals Operation Manual Produced April 2005 ...
Page 6: ......
Page 24: ...Section 1 Overview ...
Page 44: ...Section 2 General Procedure ...
Page 50: ...Section 3 Configuration ...
Page 63: ...Section 4 Specifications ...
Page 67: ...Section 5 DST1 series ...
Page 79: ...Section 6 Troubleshooting and Maintenance ...
Page 87: ...Section 7 Wiring Examples ...
Page 97: ...Appendices ...
Page 114: ...Cat No Z904 E1 01 OPERATION MANUAL DST1 series Safety I O Terminals ...