7-2 Examples of Wiring for Each Application
7-2-8
Relay Outputs with Dual Channel Mode and EDM Input
An example of the wiring and configuration when using the DST1-MRD08SL-1 is shown
below.
Wiring
V0
G0
IN0
T0
KM1
E1
V1
G1
E2
C1
C0
KM1
OUT
1
OUT
0
KM2
KM2
M
KM1
KM2
F1
F2
GND
GND
E1, E2: 24-V DC Power Supply (S8
)
KM1, KM2: Magnetic Contactors
M: 3-phase motor
F1, F2: Fuses
Configuration
Parameter
Group
Parameter Name
Value
0015 Safety Input 0 Channel Mode
Test pulse from test output
0016 Safety Input 0 Test Source
Test Output 0
Safety Input 0
0029 Dual Channel Safety Input 0/1 Mode
Single Channel
Test Output 0
0001 Test Output 0 Mode
Pulse Test Output
0006 Safety Output 0 Channel Mode
Used
Safety Output 0
0010 Dual Channel Safety Output 0/1 Mode
Dual Channel
Safety Output 1
0007 Safety Output 1 Channel Mode
Used
7-10