Appendices
A-52
CJ-series DeviceNet Units Operation Manual for NJ-series CPU Unit(W497)
Note
The refresh area types are shown in the following table.
PLC area
Refresh area type
Refresh address
CIO
1
CIO 0000 to CIO 6143
DM
3
D00000 to D32767
WR
4
W000 to W511
HE
5
H000 to H511
EM (bank 0)
8
E0_00000 to E0_32767
EM (bank 1)
9
E1_00000 to E1_32767
EM (bank 2)
A
E2_00000 to E2_32767
EM (bank 3)
B
E3_00000 to E3_32767
EM (bank 4)
C
E4_00000 to E4_32767
EM (bank 5)
D
E5_00000 to E5_32767
EM (bank 6)
E
E6_00000 to E6_32767
EM (bank 7)
F
E7_00000 to E7_32767
EM (bank 8)
10
E8_00000 to E8_32767
EM (bank 9)
11
E9_00000 to E9_32767
EM (bank 10)
12
EA_00000 to EA_32767
EM (bank 11)
13
EB_00000 to EB_32767
EM (bank 12)
14
EC_00000 to EC_32767