9 Troubleshooting and Maintenance
9-54
CJ-series DeviceNet Units Operation Manual for NJ-series CPU Unit(W497)
Event name
Slave Fixed Allocation Area Setting Failed
Event code
7464 0000 hex
Meaning
An error occurred in one of the following operations for fixed allocation of the slave.
•
Slave Fixed Allocation Area Setting 1 Switch (device variable
*_Sw2SlavFixAloc1Cmd
)
•
Slave Fixed Allocation Area Setting 2 Switch (device variable
*_Sw2SlavFixAloc2Cmd
)
•
Slave Fixed Allocation Area Setting 3 Switch (device variable *_
Sw2SlavFixAloc3Cmd
)
Source
PLC Function Module
Source details
CJ-series Unit
Detection
timing
At user operation
Error attributes
Level
Minor fault
Recovery
Error reset
Log category
System
Effects
User program
Continues.
Operation
Not affected.
System-defined
variables
Variable
Data type
Name
None
---
---
Cause and
correction
Assumed cause
Correction
Prevention
The slave function is not disabled.
Disable the slave function.
Disable the slave function.
CPU Unit is not in PROGRAM mode.
Change the CPU Unit to PROGRAM
mode.
Change the CPU Unit to PROGRAM
mode.
More than one software switch
changed to TRUE at the same time.
Or, another software switch changed
to TRUE before processing was com-
pleted for a previous software switch.
Execute the software switch opera-
tions one at a time.
Execute the software switch opera-
tions one at a time.
Attached
information
None
Precautions/
Remarks
None