Chapter 4: System Installation
Figure 4-6. Servo Power Cable
2. Connect the wire end of the cable to the user-supplied 24 VDC / 10 A regulated power
supply.
3. Attach the connector end of the cable to the Motor Power 24 VDC In (J1) connector on
the front of the AnyFeeder (see following figure).
Figure 4-7. J1 - 24 VDC In Connector
NOTE:
The five smaller pins in the center of this connector are not used by
the AnyFeeder.
AnyFeeder
Integration
Guide