Chapter 4: System Installation
1. Mount the SmartController and Front Panel.
2. Connect the Front Panel to the SmartController.
3. Connect the pendant (if purchased) to the SmartController.
Connect a jumper plug, if no pendant is being used.
4. Connect user-supplied 24 VDC power to the controller.
Refer to the
SmartController EX User’s Guide
.
5. Install a user-supplied ground wire between the SmartController and ground.
List of Cables and Parts
Part
Cable and Parts List
Part #
Part of:
Notes
A
eAIB XSYS Cable
13323-000
standard, eAIB
B
User E-Stop, Safety Gate
n/a
n/a
user-supplied
C
XUSR Jumper Plug
04736-000
13323-000
SmartController EX
D
Front Panel
90356-10358
standard
E
Front Panel Cable
10356-10500
90356-10358
standard
F
Front Panel Jumper Plug 10053-000
13323-000
SmartController EX
G
XMCP Jumper Plug
04737-000
13323-000
SmartController EX
H
T20 Bypass Plug
10048-000
10055-000
standard, T20
J
T20 Adapter Cable
10051-003
10055-000
standard, T20
K
T20 Pendant (option)
10055-000
option
L
AC Power Cable
04118-000
90565-010
user-supplied/option
M
24 VDC Power Cable
04120-000
90565-010
user-supplied/option
N1
24 VDC, 6 A Power Sup-
ply
04536-000
a
or user-supplied
N2
24 VDC, 6 A Power Sup-
ply
04536-000
90565-010
04536-000
P
RS232 Cable to
AnyFeeder
n/a
AnyFeeder
AnyFeeder
Q
Ethernet Cable, to
SmartController
n/a
n/a
user-supplied
R
Ethernet Cable, to
SmartVision MX
n/a
n/a
user-supplied
S
Ethernet Switch
(optional)
n/a
n/a
user-supplied
T
Camera and cable
n/a
n/a
user-supplied
AnyFeeder
Integration
Guide
- Page
22