2-7
2-5 Connection Diagram
2
Design
Note 3: Separate the wiring from that of the main circuit and/or the relay control circuit. If they have
to be crossed, be sure to cross them at right angles.
Note 4: Do not short-circuit between the terminals EP5 and EG5 in order to avoid breakage.
Note 5: Insulate between the analog input common terminal “FC” of the Inverter and the common
terminal (common) for the encoder signal and such peripheral devices as a sequencer.
Note 6: To connect the encoder signal line, follow the illustration below for phase relations during
the rotation of the motor.
Main circuit
power cable
Cross at right angles
I/O signal lines
Control signals including STAT, ORT, LAC,
PCLR, SAP, SAN, SBP, SBN, EAP, EAN,
EBP, EBN, POK, DSE, ZS, AP, AN, BP, BN,
FC, EP5, EG5, CM1, CM2, P24 and PLC
Separate them 10 cm apart or more
R/L1, S/L2, T/L3, U/T1, V/T2, W/T3,
P/+2, PD, RB, N/-, Ro, To etc.
EAP
EAN
EBP
EBN
EZP
EZN
Summary of Contents for 3G3AX-PG
Page 1: ...Cat No I564 E1 01 USER S MANUAL 3G3AX PG Encorder Feedback Board ...
Page 2: ......
Page 14: ...12 Contents ...
Page 15: ...Chapter 1 Overview 1 1 Overview 1 1 ...
Page 27: ...Chapter 3 Operation 3 1 Related Parameters 3 1 3 2 Precautions for Operation 3 8 ...
Page 65: ...Chapter 6 Specifications 6 1 Product Specifications 6 1 ...
Page 67: ......