2-9
2-7 Switch Setting Flow Chart
2
Design
2-7 Switch Setting Flow Chart
Start
Will disconnection
detection of the encoder A and B
phases signal be
enabled?
Will the pulse train
position command input
be used?
Turn OFF
the SWENC1.
Turn ON the SWR1 and 2.
Will disconnection
detection of the encoder Z phase
signal be enabled?
Turn ON
the SWENC2.
Turn ON
the SWENC1.
Turn OFF
the SWENC2.
Turn ON the SWR1 and 2 of
the only one unit that is
farthest from the master unit.
End
Will the multiple units
for pulse train position command
inputs be connected
in parallel?
YES
NO
NO
NO
NO
YES
YES
YES