4-16
4-4 Absolute Position/High-resolution Absolute Position Control Modes
4
Func
tions
P070
Low-speed zero return
frequency
0.00 to 10.00
0.00
Hz
P071
High-speed zero return
frequency
0.00 to 99.99/100.0 to 400.0
0.00
Hz
P072
Position range
specification
(forward)
0 to +268435456 : when APR2 is selected
0 to +1073741823 : when HAPR is selected
268435455
−
P073
Position range
specification
(reverse)
−
268435456 to 0 : when APR2 is selected
−
1073741823 to 0 : when HAPR is selected
−
268435455
−
P074
Teaching selection
00: Multi-step position command 0 (P060)
01: Multi-step position command 1 (P061)
02: Multi-step position command 2 (P062)
03: Multi-step position command 3 (P063)
04: Multi-step position command 4 (P064)
05: Multi-step position command 5 (P065)
06: Multi-step position command 6 (P066)
07: Multi-step position command 7 (P067)
00
−
C169
Multi-step speed/position
determination time
0. to 200. (
×
10 ms)
0
ms
d029
Position command monitor
−
1073741823 to +1073741823
−
−
d030
Current position monitor
−
1073741823 to +1073741823
−
−
C001 to
C008
Multi-function inputs 1 to 8
selection
45: ORT (orientation)
54: SON (servo ON)
66: CP1 (position command selection 1)
67: CP2 (position command selection 2)
68: CP3 (position command selection 3)
69: ORL (zero return limit signal)
70: ORG (zero return startup signal)
71: FOT (forward driving stop)
72: ROT (reverse driving stop)
73: SPD (speed/position switching)
−
−
C102
Reset selection
03: Does not initialize internal data during re-
set.
0
−
Parameter No.
Function name
Data
Default setting
Unit
Summary of Contents for 3G3AX-PG
Page 1: ...Cat No I564 E1 01 USER S MANUAL 3G3AX PG Encorder Feedback Board ...
Page 2: ......
Page 14: ...12 Contents ...
Page 15: ...Chapter 1 Overview 1 1 Overview 1 1 ...
Page 27: ...Chapter 3 Operation 3 1 Related Parameters 3 1 3 2 Precautions for Operation 3 8 ...
Page 65: ...Chapter 6 Specifications 6 1 Product Specifications 6 1 ...
Page 67: ......