4-14
4-3 Pulse Train Position Control Mode
4
Func
tions
Note 2: Orientation stop position is defined as 4096 (0 to 4095) divisions of one forward rotation from the reference
point. (The number of divisions is fixed to 4096, regardless of the encoder’s number of pulses.)
The reference point is defined as the point where the pulse is input between EZP and EZN. Below is the layout
of the stop target position. (Positive-phase connection)
Orientation stop position conceptual drawing
Position of Z pulse
Reference point
0
1024
3072
2048
Motor shaft viewed from motor
shaft load side