LVS-7000 Operations Manual Version 5.6.X
LVS-7000 Operations Manual Version 5.6.X
Page 140 of 187
ForegroundSize allows the user to increase or decrease the size of detected Blemishes.
BackgroundSensitivity
works the same way as ForegroundSensitivity but it is meant to find contrast
differences in the label’s background.
BackgroundSize allows the user to increase or decrease the size of detected Blemishes.
WanderX and WanderY - Control how far individual pixels are allowed to move in relation to the rest of
the streak/void line. This is different from controlling how far the entire streak/void line can move in
relation to the rest of the image. Motion of the entire line is controlled with the following settings:
StreakVoidX and StreakVoidY.
StreakVoidX controls how far the streak/void line is allowed to move in the X direction (default is 1/8").
StreakVoidY controls how far the streak/void line is allowed to move in the Y direction (default is 1/8").
[StreakVoid]
Contrast=80
ForegroundSensitivity=80
ForegroundSize=0.002
BackgroundSensitivity=80
BackgroundSize=0.002
WanderX=2
WanderY=2
StreakVoidX=0.125
StreakVoidY=0.125
Sync Parameters:
The Sync Parameters are used for setting the system to be able to lock onto the customers’ labels.
FastSync tells the system to not resync when the “Start” button in pushed. This is needed on LVS-7000
systems to not miss the first label. 0 is off. 1 is on.
HopX and HopY tracks the movement of the labels in the horizontal and vertical direction.
Log is to be used by a qualified
Omron Microscan
technician only.
SyncErrorsInARowBeforeResync. If the 7000 loses synchronization, this is the number of repeats allowed
to pass before the 7000 attempts to sync agan.
[Sync]
FastSync=0
HopX=0.0625
HopY=0.125
Log=
SyncErrorsInARowBeforeResync=3
System Parameters:
The system parameters control some of the user interface.
A5Follows tells the software what I/O Line the system should use to trigger a beep.
AcceptReplaceInputTimer – Setting this to anything greater than zero will activate the ability of the
customer to click the “Accept” or “Replaced” buttons remotely using user inputs 7 and 8. The value
entered dictates the time in milliseconds between input pulses when triggering these buttons remotely. A
value of 500, for instance, means that the buttons cannot be clicked via user inputs any faster than twice
a second (500 millisecond delay). User input 7 is linked to the “Accept” button and user input 8 is linked to
the “Replaced” button.
AddMissingTriggers - When enabled (set to some value other than zero), the system will estimate where
photoeye triggers should have occurred and create phantom triggers. This enables customers to have
photoeye triggers on every plate repeat instead of on every label
AutoBreakRoll should be enabled when used with turrets.