rewinder. Multiple ports can be triggered by adding the numbers into a string. 345 would activate ports
(3), (4), (5) at software start up.
Preset is the default starting location of the encoder pulse count.
RegradeOnReverse tells the software if labels needs to be re-graded when a Rewinder winds the labels
back to a point then forward again.
o
RegradeOnReverse=0 – No previously checked labels are re-graded. Do not re-grade after
moving in reverse.
o
RegradeOnReverse=1 – Re-grades images after moving in reverse and advancing if operator has
pressed Replaced.
o
RegradeOnReverse=2 – All repeats are re-graded and put into log.
o
RegradeOnReverse=3 – (Must have StopLoggingOnErrors set to 1) Will re-grade only the
repeats
that have been marked Replaced; otherwise, re-grading will begin with the first repeat
after the
(one and only one) defect label not marked as replaced has passed the camera (any
subsequent
repeat defects prior to the stop motion signal will appear in the error log, but be
deleted after the
stop motion signal has been sent).
o
RegradeOnReverse=4 – LinesPerInch must be exactly 400.0 not 409.6. Error log entries will be
color coded as follows:
White
– Next error at the inspection table when stopped (Accept enabled; Replaced not
enabled)
Yellow
– Next error, web moving or stopped but not at inspection table (buttons not
enabled)
Cyan
– NOT Next error, but stop motion has been sent (buttons not enabled)
Gray
– NOT Next error, but web stopped and error is at splice table (buttons not enabled)
Red
– Next error at splice table, web stopped (accept not enabled, replaced enabled)
System will begin inspecting once error has reached camera all other errors will be
deleted and re-inspected.
SetRunStatusOutput sets an output signal to high when the system is running. Enter any number from 0
to
8. Zero disables the output signal and any number from 1 to 8 sets the output signal high when the
system
is running and low when the system is not running.
o
SetRunStatusOutput=0 disables the output signal.
o
SetRunStatusOutput=1 [and any number up to 8] sets the output signal to high.
ShowRollerOnReverse determines if a Roll-to-Roll will be displayed when running in reverse.
o
ShowRollerOnReverse=0 – Shows the actual image when running in reverse
o
ShowRollerOnReverse=1 – Shows the Roll-to-Roll image when running in reverse.
SimulateStopMotion should only be configured by a qualified
Omron
Microscan representative.
SpliceToCamera is the distance from the camera to the upstream splice table.
StopLoggingOnError=0 – When a single error occurs, all logging stops until the rewinder is backed up.
Then, the LVS-7000 re-inspects the label after it moves back under the camera and continues logging
from that point.
The StopMotionDelay is the minimum allowed distance that
Omron Microscan
has determined that the
Stop
Motion Output signal can be sent without missing any outputs. This should not be changed unless
instructed by a qualified
Omron Microscan
representative.
UseVSyncInput – the system uses V-SYNC on input 8 of I/O board from the Framegrabber.
[Encoder]
AcceptReplaceOutputString=G10250
ArrowOffset=0
AutoRejectDistance=0
CameraToInspection=100
EncoderDirecton=0
InitialCommand=E0
OverrideLine=0
Preset=0