8/10/2015
21
921458000_09_003
«EXIT TIME». Is the time from when the arming password is entered until
the actual arming of the system. Pressing (*) reveals a new screen where
the current exit time is shown. By default it is 45 seconds. We enter the new
required exit time with 2 digit numbers (05-99 2 digits are mandatory) i.e. 6
and 0 for 60 seconds. The system stores the value and returns to the menu
«SETTINGS».
«ALARM TIME». Is the time that the siren is sounded. This time counts from
the instance that all activation devices have stopped activating the panel.
Select 1 or 2 minutes, press (*). The system stores the value and returns to
the menu
«SETTINGS».
«EXTRA EXIT TIME.» Is the time that is added to the exit time when the
system is activated with a password which has an additional delay or by a
zone with delay.
«SECTIONS EXIT TIME». With this selection if we will have an exit time for
the sections (A, B, C). We must reply YES or NO for each subsection.
«ENTRANCE DELAY BEEPS.» Select if the built-in buzzer will sound during
the entry time.
«EXIT DELAY BEEPS.» Select if the built-in buzzer will sound during the exit time.
«BEEP PARTIALLY ARMED.» Select if the built-in buzzer will sound during the exit time in case of a
partial arming of the system (section arming
Α, Β or C).
«ARM WITHOUT CODE» Select if the system can be armed without a password, with the use of the
keys A. B. C. ABC. The selection only affects the arming, for the disarming a password is always
required.
«ARMED SYS INDICATORS». We have 2 selections «OFF» or «ON». With the selection «OFF» the
indicators LEDs are not lit when the panel is armed.
«IDLE BACKLIGHT MODE» This option regards the illumination of the display and the keypads during
the idle state of the system. The idle state is the state where there is not alarm and no key has been
pressed for 30 seconds. We have 3 options. ALWAYS OFF, ONLY WHEN DISARMED which means
off in an armed system and on in a disarmed system and ALWAYS ON.
«DOUBLE BUTTON PANIC» We select if a panic signal alarm can be issued from the keyboard. If we
select YES and we simultaneous press for two seconds the keys C and ABC then a panel alarm will
be produced.
«RECORD OUTPUTS EVENT». We select if the state of the outputs will be logged as individual
events (
Ρ1, Ρ2).
«AUTOMATIC BYPASS» By selecting YES, all zones that have be programmed with bypass
capabilities (see zone programming), if during the arming are active (i.e. an open window) are
bypassed automatically by the system. When the zones are deactivated (i.e. the window has closed)
they are automatically activated. If we select NO then if there are active zones during the arming
procedure the system will request a bypass confirmation for each active zone.
«ANNUAL CHECK WARNING» We select if the system will issue a reminder signal
after 1 year of operation to reminder the user for the annual technical inspection.