Zone connections
Connecting the panel with radars (infrared movement detectors, PIR) or other devices that require
power. For the connection, 4 cables are required (6 if the TAMPER is connected). The 2 cables are
connected to the (12V) and (-) of the panel and provide power to the respective terminals of all the
detectors. The other 2 cables connect in series
the contacts RELAY (NC) of all the detectors of
the zone and the resistors found on the terminals
of the panel. The diagram above provides
examples for connecting 1 or 2 detectors on the
zones.
For the connection of magnetic contacts or other
devices that do not require power only 2 cables
are required by which we connect in series all the
zone contacts and the terminal resistor found on
the
panel. The above diagram shows a connection
with 1 or 2 magnetic contacts.