By pressing the (*) key we see:
We make the required selection of the function that we want the
timer to do and press the key (*). The system confirms the
selection.
The event memory logs the arming or disarming of the system but
also shows that the event has been launched by a timer.
Finally if we want to delete a timer select
«DELETE TIMER» and we see:
Enter the number of the timer that we want tot delete.
Zone Programming
The next option in the TECHNICIANS MENU is
«ZONES» via which we can adjust the parameters of
the zones. When the selection is made we see the name of the zone for 2 seconds and then:
We select the required zone and after a while we can see in
sequence all the menus where we can program the zone. In
every menu the cursor highlights the current setting. First we
have the menu
«ZONE MODE» which gives us the options
below:
«DISABLE OFF». The zone does not function and cannot
issue and alarm or fault signal. In this state are all the zone
that are not physically installed on the system (i.e zones 09-
16 if there in no expansion card). Usually we set to this state
all the zones that are not used.
«ZONE WITH DELAY». The zone will issue an alarm after an entrance delay. This selection is used
for the magnetic contacts that are used for the main entrance and also for the radar the will detect the
user before he reaches the panel to disarm it.
«"ZONE WITHOUT DELAY». The zone will issue an immediate alarm. This selection is used for radar
detector and magnetic contact that are used in other areas.
«PANIC». This zone will issue an immediate alarm even if the panel is disarmed. It will also produce a
panic alarm message if a telephone dialer is installed. It can be used on zones that have a panic
button.