8/10/2015
6
921458000_09_003
2.1.
Armed system indication
When the system is armed then next to the clock, instead of
the Olympia electronics logo there is a lock symbol. Next to
the lock symbol we can see which sections are armed. In
this example we can see that the system is partially armed
because only the B section is armed. If the system was fully
armed then the symbols
Α, Β, C would be displayed. When
the system is disarmed then the lock is removed and the
Olympia electronics logo is displayed.
2.2.
Advanced operations
Pressing the key (
*
) the display shows:
Using the up and down keys (keys 2 and 8) we can move the
cursor upwards or downward, using the key (
*
) we can make the
required selection or using the (#) we can go one level backward
or cancel a selection.
By selecting
«BYPASS ZONES» we see :
Here we can select which zones are disabled (will not be armed)
during the next arming of the system. For example, if we enter 2and
then immediately 4, this means that the next time the system is
armed, zones 2 and 4 will be disabled. If a zone blinks, this means
that it is preventing the system from arming. If it is blackened then
this means that it is disabled. If it is blinking and blackened then this
means that it is disabled but would prevent the panel from arming if
it was not disabled.
Selecting
«ZONES CONDITION»:
Here we can test the good operation of the zones and the devices
connected to them. For examples, if a magnetic contact of a
window is connected to zone 4 and the window opens then the
message of the display from
«ALL ZONES OK» will be erased and
the indication 04 will start to blink. As soon as the window is closed
the screen will display the previous message
«ALL ZONES OK»
With this method we can test the good operation of all the detectors
and magnetic contacts.
For the selection
« MASTER OR TECH MENU » you will find
information in the section Main User Menu one page 8.
MENU
BYPASS ZONES
ZONES CONDITIONS
MASTER OR TECH MENU
ALL EVENTS
MANUAL OUTPUTS CHECK
INFORMATION
____BYPASS ZONES____
2 4
_____________________
CHOOSE FROM 1-4
___ZONES CONDITION ___
ALL ZONES OK